Chapter 8
Performance Monitoring
Procedure: Select Far-End PMs on the Performance Monitoring Screen
Open the electrical or optical card of choice. To do so, double-click the card graphic in the main (node)
Step 1
view or right-click the card and select Open Card. (Clicking a card once highlights the card only.)
From the card view, click the Performance tab.
Step 2
Click the Far End button.
Step 3
Click the Refresh button. All PMs recorded by the far-end node for the selected card on the outgoing
Step 4
signal are displayed.

8.1.4 Using the Signal-Type Menu

Use the signal-type menus to monitor PMs for near-end or far-end signals on a selected port. Different
signal-type menus appear depending on the card type and the circuit type. The appropriate types (DS1,
DS3, VT path, STS path, OCn section, line) appear based on the card. For example, the XTC-28-3 has
DS3, DS1, VT path, and STS path PMs.
Monitoring screen for an OC48 card.
Figure 8-4
June 2002
Signal-type menus for an OC48 card
Signal-type menu
Using the Performance Monitoring Screen
Figure 8-4
shows the signal-type menus on the Performance
Cisco ONS 15327 User Documentation, R3.3
8-7