Table 8-22 Far-End Line Layer PMs for the OC-12 Card (continued)
Parameter
UAS-L
FC-L
8.5.3 OC-48 Card Performance Monitoring Parameters
Figure 8-18
detected on the ASICs produce performance monitoring parameters for the OC-48 cards.

Figure 8-18 Monitored signal types for the OC-48 cards

ONS 15327
PMs on the protect STS are not supported for BLSR. The XX in the illustration above represents all PMs
Note
listed below with the given prefix and/or suffix.
June 2002
Definition
UAS-L is a count of the seconds when the line is considered unavailable
at the far end. A line is considered unavailable at the onset of ten
consecutive seconds that qualify as SES-LFEs, and continues to be
unavailable until the onset of ten consecutive seconds that do not qualify
as SES-LFEs.
FC-L is a count of the number of far-end line failure events. A failure
event begins when RFI-L failure is declared and ends when the RFI-L
failure clears. A failure event that begins in one period and ends in another
period is counted only in the period where it began.
shows the signal types that support far-end PMs.
Near End
OC-N Signal
DS1
OC-N
Performance Monitoring for Optical Cards
Figure 8-19
Far End
Fiber
OC-N
Cisco ONS 15327 User Documentation, R3.3
shows where overhead bytes
OC-N Signal
ONS 15327
DS1
8-33