Server chassis

No.
1
USB port 0
(USB0)
2
USB port 1
(USB1)
3
Forced power off
switch (POFF)
4
Power LED
(PWR)
5
Alarm LED
(ALM)
6
Warning LED
(WRN)
7
Identify LED
(LID)
Figure 1-34 Front panel in server chassis
Table 1-29 LEDs, switches, and connectors on front panel
Name
State
-
-
-
Green-On Main powers of any server blades are turned on.
Green-
Blink
Amber-On All server blades are under stand-by condition
Amber-
Blink
Off
Red –On
Off
Amber-On Non-serious error has occurred. The server chassis
Off
Blue-On
Off
Introduction
Hitachi Compute Blade 500 Series System Service Manual
Description
Shared USB ports in the chassis
Supported device:
- LCD touch console
- USB Memory and USB DVD-ROM drive
Press and hold it for four seconds or more, then the
main power is turned off.
The system is shutting down by the management
module. Keep blink until all main powers are turned
off in all server blades.
Initializing process below;
- The management module is booting.
- The server blade is initializing
- The switch module is booting.
Power is not supplied to the server chassis.
A serious error has occurred in the server chassis.
Please contact Hitachi Data Systems Technical
Support. See the Getting Help section in the Preface
of this manual.
Normal operation
can continue to operate, but any modules have
warning or error status. See the Getting Help
section in the Preface of this manual.
Normal operation
The chassis is identified. This LED is controlled by
the Web console, Blade Server Manager, or the
Server Conductor
The chassis is not identified.
1-25