(B) Press and hold the Power switch for four seconds or more
This procedure forces the management module to power off.
1
Ensure that Power LED lights in green.
.
2
Press and hold the Shutdown switch until Power LED turns to light in
.
amber.
3
Release the Shutdown switch.
.

Power off the switch module

Use the following procedure to power down the switch module.
(A) Use a Web console
This procedure initiates a remote power off for the failed switch module.
1
Ensure that Power LED lights on green.
.
2
Logon to the Web console and select Resource.
.
3
Select Modules > All Modules > Switch modules > the failed
.
module.
4
Select Condition tab.
.
5
Click Power OFF.
.
6
Ensure that the shutdown was completed and Power LED lights in amber.
.
4-62
Figure 4-53 Power off procedure of failed management module
Figure 4-54 Power LED and Shutdown switch