Advertisement

Hitachi Advanced Server
DS120 Hardware Guide
This guide provides the system overview and specifications for Hitachi Advanced Server
DS120, including hardware component descriptions, ports, network interface cards, and LEDs.
MK-97HAS010-00
April 2018

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi Advanced Server DS120

  • Page 1 Hitachi Advanced Server DS120 Hardware Guide This guide provides the system overview and specifications for Hitachi Advanced Server DS120, including hardware component descriptions, ports, network interface cards, and LEDs. MK-97HAS010-00 April 2018...
  • Page 2 Licensee may not make any other copies of the Materials. "Materials" mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3: Table Of Contents

    ABLE OF ONTENTS ABLE OF ONTENTS About the System Introduction ............1 System Features.
  • Page 4 ONVENTIONS Conventions Several different typographic conventions are used throughout this manual. Refer to the following examples for common usage. Bold type face denotes menu items, buttons and application names. Italic type face denotes references to other sections, and the names of the folders, menus, programs, and files.
  • Page 5 RECAUTIONARY EASURES Precautionary Measures Read all caution and safety statements in this document before performing any of the instructions. To reduce the risk of bodily injury, electrical shock, fire, and equipment dam- age, read and observe all warnings and precautions in this chapter before installing or maintaining your system.
  • Page 6 RECAUTIONARY EASURES Table 1: Warning and Cautions (Continued) The enclosure is designed to carry only the weight of the system sled. Do not use this equipment as a workspace. Do not place additional load onto any equipment in this system. Indicates two people are required to safely handle the system.
  • Page 7 RECAUTIONARY EASURES To reduce the weight for easier handling, remove any easily detachable compo-  nents. Never lift or move your system soley by the handle on the component.  Power and Electrical Warnings CAUTION! AKE SURE THE SYSTEM IS REMOVED FROM THE RACK BEFORE SERVICING ANY NON HOT PLUG COMPONENTS HE BUS BAR CLIPS MUST BE DISCONNECTED FROM THE POWER SYSTEM IN ORDER TO FULLY SEPARATE THE SYS TEM FROM THE POWER SOURCE...
  • Page 8 RECAUTIONARY EASURES Install equipment in the rack from the bottom up, with the heaviest equipment at the bot- tom of the rack. Extend only one piece of equipment from the rack at a time. You are responsible for installing a main power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must be labeled as controlling power to the entire unit, not just to the system(s).
  • Page 9 RECAUTIONARY EASURES Cooling and Airflow CAUTION! AREFULLY ROUTE CABLES AS DIRECTED TO MINIMIZE AIRFLOW BLOCKAGE AND COOLING PROBLEMS PROPER COOLING AND AIRFLOW OPERATE THE SYSTEM ONLY WITH THE CHASSIS COVERS AIR DUCT INSTALLED PERATING THE SYSTEM WITHOUT THE COVERS AIR DUCT IN PLACE CAN DAMAGE SYSTEM PARTS O INSTALL THE COVERS AIR DUCT...
  • Page 10 RECAUTIONARY EASURES Electrostatic discharge (ESD) and ESD protection: ESD can damage drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts.
  • Page 11 RECAUTIONARY EASURES WARNING! The system is safety certified as rack-mounted equipment for use in a server room or computer room, using an approved customer rack. The enclosure is designed to carry only the weight of the system sled. Do not place additional load onto any equipment.
  • Page 12 About the System This guide provides the system overview and specifications for Hitachi Advanced Server DS120, including hardware component descriptions, ports, network interface cards, and LEDs.
  • Page 13: Introduction

    BOUT THE YSTEM NTRODUCTION 1.1 Introduction This document provides an overview of the hardware features of the chassis, troubleshooting information, and instructions on how to add and replace components of the server. System Features The system comprises a 1U/30.7” long chassis. Major features include: ®...
  • Page 14 BOUT THE YSTEM YSTEM EATURES Table 1.1: System Specifications (Continued) PECIFICATIONS ESCRIPTION Onboard (Intel® C624): (8) SATA 6Gbps port with (2) mini-SAS HD connector  Storage controller (6) sSATA 6Gbps port with (1) mini-SAS HD connector (reserved) and  (2) 7-pin SATA port (reserved for SATA DOM) Dedicated GbE management NIC port from PHY RTL8211 to BMC ...
  • Page 15: Sku Information

    BOUT THE YSTEM YSTEM EATURES Table 1.1: System Specifications (Continued) PECIFICATIONS ESCRIPTION 100-120/200-240Vac, 50/60Hz, 6.5/3.3A or 240Vdc, 3A (Per PSU inlet) for  PSU:500W and 800W System rating 100-120/200-240Vac, 50/60Hz, 7.4/4A or 240Vdc, 3.7A (Per PSU inlet) for  PSU:800W -39V- -72Vdc, 28A max.
  • Page 16: Package Contents

    BOUT YOUR YSTEM ACKAGE ONTENTS 1.2 Package Contents (1) DS120-1U system  (2) processor heat sinks  (1) power supply unit  (1) power cord  (optional) Note: For exact shipping contents, contact your sales representative.
  • Page 17: A Tour Of The System

    BOUT THE YSTEM OUR OF THE YSTEM 1.3 A Tour of the System System Overview The server is available as a 2.5” storage drive configuration. The 2.5” storage drive system overview is displayed in the following image: Figure 1. 2.5” Storage Drive System Component Overview Table 2: Component Overview ESCRIPTIONS Front control panel...
  • Page 18: System Front View

    BOUT THE YSTEM YSTEM RONT Table 2: Component Overview (Continued) ESCRIPTIONS Riser assembly (CPU0) Support PCIe add-on card installation with riser feature. PSU assembly Redundant power supply unit assembly SuperCap carrier Housing SuperCap using in SAS mezzanine card or SAS add-on card DIMM slots (12) DDR4 DIMM slots per CPU Fan module...
  • Page 19: Front Control Panel (Fcp)

    BOUT THE YSTEM YSTEM Front Control Panel (FCP) Reset Figure 3. Front Control Panel Table 4: Front Control Panel Descriptions ESCRIPTIONS Power on / off Power button with Blue on - S0 system power on; Off - S5 system power off Reset button Soft reset system function Reset...
  • Page 20: System Rear I/O

    BOUT THE YSTEM YSTEM Table 5: System Rear View (Continued) EATURE ESCRIPTIONS Power sub-system Main power supply unit (PSU1). See Power Sub-System on page 9. Expansion slot PCIe expansion slot with LP MD-2 (CPU0) Expansion slot PCIe expansion slot with LP MD-2 (CPU1) Expansion slot PCIe expansion slot with LP MD-2 (CPU1) Expansion slot...
  • Page 21: Power Sub-System

    BOUT THE YSTEM YSTEM Power Sub-System PSU LED Figure 6. PSU to Mainboard Module Description A single power supply unit (default) is supplied in the system. A secondary PSU is available for redundancy functionality. Table 7: AC Power Supply Units by Model AC I NPUT 2 x 500W and 800W Titanium/Platinum...
  • Page 22: Hdd / M.2 Adapter Configuration

    HDD / M.2 A BOUT THE YSTEM DAPTER ONFIGURATION HDD / M.2 Adapter Configuration The systems are available as a full 2.5” SKU. Within the HDD array, the HDD enumeration is as follows: Full 2.5” HDD Configuration HDD0 HDD2 HDD4 HDD6 HDD8 HDD10...
  • Page 23: Nvme Ssd M.2 Adapter Add-On Card (Optional)

    HDD / M.2 A BOUT THE YSTEM DAPTER ONFIGURATION NVMe SSD M.2 Adapter Add-On Card (Optional) M.2 Slot2 M.2 Slot1 Figure 8. M.2 Slot Number...
  • Page 24: Led Status Descriptions

    LED S BOUT THE YSTEM TATUS ESCRIPTIONS LED Status Descriptions Front Control Panel LEDs For location of the FCP, see System Front View on page 6. Reset Power LED ID LED Status LED Figure 9. Front Control Panel LEDs Table 13: Front Control Panel LEDs Behavior LED S OLOR ONDITION...
  • Page 25: Storage Drive Led

    LED S BOUT THE YSTEM TATUS ESCRIPTIONS Storage Drive LED Front 2.5” Storage Drive LED Status Behavior Active LED Status / Fault LED Figure 11. 2.5” Storage Drive LED Identification The following LED behavior table represents LED conditions. Table 15: 2.5” Storage Drive LED Status Behavior OLOR ONDITION ESCRIPTIONS...
  • Page 26 Hitachi Vantara Corporate Headquarters Regional Contact Information 2845 Lafayette Street Americas: +1 866 374 5822 or info@hitachivantara.com Santa Clara, CA 95050-2639 USA Europe, Middle East and Africa: +44 (0) 1753 618000 or info.emea@hitachivantara.com www.HitachiVantara.com Asia Pacific: +852 3189 7900 or info.marketing.apac@hitachivantara.com...

Table of Contents