Appendix A Parameter List
A.1 System Management
•
Bad data
Description
•
Pinned data
Description
•
Not Ready
Description
•
Remote Path Error during Data Transfer
Description
•
Remote Path Error of no Data Transfer
Description
•
REC Buffer Halt (Path Error)
Description
•
REC Buffer Halt (Overload)
Description
•
REC Buffer Halt (Other Error)
Description
Select whether to notify when a bad sector is detected in the drive. When notifying,
select the notification method.
Select whether to notify when pinned data (*1) is detected or disappears. When
notifying, select the notification method.
*1:
"Pinned data" is the data left in the cache due to unsuccessful write-back to the
drive from the cache area.
Select whether to notify when the ETERNUS DX is in "Not ready" status (*1). When
notifying, select the notification method.
*1:
"Not ready" is the status in which the ETERNUS DX cannot operate properly due to a
cause such as failures in multiple parts.
Select whether to notify when an error occurs in a copy path and a copy session that is
not suspended exists. When notifying, select the notification method.
Select whether to notify when an error occurs in a copy path and a copy session that is in
one of the following conditions exists. When notifying, select the notification method.
•
No REC sessions exist
•
All of the REC sessions are suspended
Select whether to notify when an REC buffer halt caused by copy path error occurs. When
notifying, select the notification method.
Select whether to notify when an REC buffer halt caused by overload occurs. When
notifying, select the notification method.
Select whether to notify when an REC buffer halt caused by an error occurs. When
notifying, select the notification method.
732
ETERNUS Web GUI User's Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0