Appendix A Parameter List
A.1 System Management
Bad data
Description
Pinned data
Description
Not Ready
Description
Remote Path Error during Data Transfer
Description
Remote Path Error of no Data Transfer
Description
REC Buffer Halt (Path Error)
Description
REC Buffer Halt (Overload)
Description
REC Buffer Halt (Other Error)
Description
Select whether to notify when a bad sector is detected in the drive. When notifying,
select the notification method.
Select whether to notify when pinned data (*1) is detected or disappears. When
notifying, select the notification method.
*1:
"Pinned data" is the data left in the cache due to unsuccessful write-back to the
drive from the cache area.
Select whether to notify when the ETERNUS DX is in "Not ready" status (*1). When
notifying, select the notification method.
*1:
"Not ready" is the status in which the ETERNUS DX cannot operate properly due to a
cause such as failures in multiple parts.
Select whether to notify when an error occurs in a copy path and a copy session that is
not suspended exists. When notifying, select the notification method.
Select whether to notify when an error occurs in a copy path and a copy session that is in
one of the following conditions exists. When notifying, select the notification method.
No REC sessions exist
All of the REC sessions are suspended
Select whether to notify when an REC buffer halt caused by copy path error occurs. When
notifying, select the notification method.
Select whether to notify when an REC buffer halt caused by overload occurs. When
notifying, select the notification method.
Select whether to notify when an REC buffer halt caused by an error occurs. When
notifying, select the notification method.