Data logging function

The following is the list of special relay areas relating to the data logging function.
No.
Name
SM1200
Auto logging setting file and
registration status
SM1201
SD memory card setting file in
use flag
SM1202
Data memory setting file in
use flag
SM1210
Data logging setting No.1
Data logging preparation
SM1211
Data logging setting No.1
Data logging start
SM1212
Data logging setting No.1
Data logging collection
SM1213
Data logging setting No.1
Data logging end
SM1214
Data logging setting No.1
Data logging trigger
SM1215
Data logging setting No.1
After data logging trigger
Data stored
Details
Off: Mismatch
• This relay is on when the auto logging setting executed
On: Matching
(registered) matches with the content of the configuration
file stored in the target memory. This relay is off when the
setting does not match with the content.
Off: Not used
• This relay switches to on when the data logging
On: In use
configuration file stored in an SD memory card is being
used. This relay switches to on when one or more data
logging of the settings No.1 to 10 is registered.
• The ON state is maintained even when the data logging
later enters into suspend/waiting for start without
collection/waiting for RUN without collection mode.
However, the relay switches to off when all the data
logging stops.
Off: Not used
• This relay switches to on when the data logging
On: In use
configuration file stored in the data memory is being
used. This relay switches to on when one or more data
logging of the settings No.1 to 10 is registered.
• The ON state is maintained even when the data logging
later enters into suspend/waiting for start without
collection/waiting for RUN without collection mode.
However, the relay switches to off when all the data
logging stops.
Off: Not prepared
• This relay switches to on when the data logging
On: Prepared
preparation is completed.
• The ON state is maintained even when the data logging
later enters into suspend/waiting for start without
collection/waiting for RUN without collection mode. This
relay switches to off when the data logging stops.
Off: Suspended/waiting for
• This relay switches to on when the data logging starts.
start
The relay turns off when the data logging is in suspend/
On: Start
waiting for start without collection mode. Associated
special relay, such as Data logging collection, Data
logging end, Data logging trigger, and After data logging
trigger, switches to off simultaneously.
• This relay also switches to off when the CPU module is
moved from RUN to STOP mode and therefore the data
collection is halted.
Off: Not in progress
This relay switches to on when the data logging starts data
On: In progress
collection.
Off: Not completed
This relay switches to on when the data logging is
On: Completed
completed. For continuous logging, the corresponding bit
switches to on when writing reaches the maximum number
of storage files and data logging is completed (with "Stop"
set for the operation at the time when the number of save
files exceeds the limit). For trigger logging, the
corresponding bit switches to on when data collection for
the specified number of records has been completed
followed by writing into the SD memory card after the
trigger condition was satisfied. The bit also switches to on
when an error is generated (except for data logging error
caused by online program change) during the data logging
execution.
OffOn: Triggered
The system switches this relay to on when the specified
trigger condition is satisfied.
Off: Not post triggering
• This relay switches to on once data logging triggering
On: Post triggering
occurs. The ON state is maintained even when the data
logging is completed. However, this relay is off when the
data logging is in suspend/waiting for start without
collection/stop mode
• This relay also switches to off when the CPU module is
moved from RUN to STOP mode and therefore the data
collection is halted.
Set by (setting
timing)
S (Status change)
S (Status change)
S (Status change)
S (Initial)
S (Status change)
S (Status change)
S (Status change)
S (Status change)
S (Status change)