Appendix 13
This section describes added and enhanced functions of the CPU module and the engineering tool, as well as the firmware
versions of the CPU module and software versions of the engineering tool corresponding to the functions.
The firmware update function enables users to update the firmware versions of the CPU module. For the
target CPU modules and how to update the firmware version, refer to the following.
 MELSEC iQ-R Module Configuration Manual
: Supported from the first released product, : Not supported, : Function usable regardless of the software version
Added or enhanced function
Mounting of MELSEC iQ-R series
modules occupying two slots
SFC support
Duplication check for POU
Background processing of program
transfer (writing the program restoration
information) during changing a program
online
CPU module data backup/restoration
function
Redundant function
Redundant power supply system
Label initialization function
Firmware update function (Firmware
update using the engineering tool)
Firmware update function (Firmware
update using an SD memory card)
External input/output forced on/off
function
Multiple CPU system
Program restoration information write
selection
File batch online change of FB files and
the global label setting file
File batch online change when the
program memory does not have enough
free space
Error detection invalidation setting
'Communication load status' (Un\G100 to
Un\G103)
Online change (SFC block)
Omission of writing files that are not
changed
Device test with execution conditions
Added and Enhanced Functions
F: Firmware version of the CPU module
S: Software version of the engineering tool
O: Version of the other tools
Process mode
Redundant mode
F: 
F: 
S: 1.007H
S: 1.007H
F: 03
F: 18
S: 1.020W
S: 1.050C
*1*2*3
O: 1.54G
F: 04
F: 04
S: 1.025B
S: 1.025B
F: 10
F: 15
S: 1.022Y
S: 1.045X
F: 20
F: 20
S: 
S: 
F: 04
S: 1.025B
F: 04
F: 04
S: 1.025B
S: 1.025B
F: 04
F: 04
S: 1.025B
S: 1.025B
F: 24
F: 24
S: 1.065T
S: 1.065T
F: 14
F: 14
S: 
S: 
F: 15
F: 15
S: 1.045X
S: 1.045X
F: 
S: 1.007H
F: 13
F: 15
S: 1.040S
S: 1.045X
F: 13
F: 13
S: 1.040S
S: 1.040S
F: 13
F: 13
S: 1.040S
S: 1.040S
F: 14
F: 14
S: 
S: 
F: 22
F: 22
S: 
S: 
F: 20
F: 20
S: 1.055H
S: 1.055H
F: 18
F: 18
S: 1.050C
S: 1.050C
F: 20
F: 20
S: 1.055H
S: 1.055H
Reference
For the applicable modules, refer to the
following.
MELSEC iQ-R Module Configuration Manual
MELSEC iQ-R Programming Manual
(Program Design)
GX Works3 Operating Manual
GX Works3 Operating Manual
Page 308 CPU MODULE DATA BACKUP/
RESTORATION FUNCTION
Page 370 REDUNDANT FUNCTION
MELSEC iQ-R Module Configuration Manual
Page 522 LABEL INITIALIZATION
FUNCTION
MELSEC iQ-R Module Configuration Manual
MELSEC iQ-R Module Configuration Manual
Page 232 External Input/Output Forced On/
Off Function
MELSEC iQ-R Module Configuration Manual
*4
Page 741 Program Restoration Information
*4
Write Selection
Page 193 File batch online change
Page 193 File batch online change
Page 207 Error detection invalidation setting
MELSEC iQ-R Ethernet User's Manual
(Application)
MELSEC iQ-R Programming Manual
(Program Design)
GX Works3 Operating Manual
Page 241 Device Test with Execution
Conditions
Appendix 13 Added and Enhanced Functions
A