Mitsubishi Electric MELSEC iQ-R Series User Manual page 183

Process cpu module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Function
RAS function
Scan monitoring
function
Self-diagnostics
function
FB hierarchy
information
Error clear
Event history
function
Online module
change function
Program cache
memory auto
recovery function
Remote operation
Boot operation
Monitor
Circuit monitor
function
Device/buffer
memory batch
monitor
Watch
Program monitor
list
Interrupt program
monitor list
Test function
External input/
output forced on/
off function
Device test with
execution
condition
Data logging function
SFC function
PID control function
Process control function
Description
Detects a hardware failure or program error by monitoring
that the END processing is performed within a set scan
time.
Self-diagnoses the CPU module to see whether an error
exist or not.
Displays the FB hierarchy information of the function
block with an error in the "Module Diagnostics" window.
Batch-clears all the continuation errors being detected.
Collects operations executed and errors detected from
the modules, and saves them in the CPU module. The
saved logs can be checked in chronological order.
Replaces the module/unit without stopping the system.
Automatically detects and recovers the data stored in the
program cache memory of the CPU module at the time of
program execution if the data is overwritten due to the
factors such as excessive electrical noise.
Remotely controls the operating status of the CPU
module without switch operation.
Transfers files in the SD memory card to the built-in
memory of the CPU module when the CPU module is
powered off and on or reset.
Checks the status of a running program on the program
editor.
Monitors values in devices and buffer memory using the
engineering tool connected.
Registers devices and labels, and checks the current
values.
Monitors the execution time of each program and the
number of executions using the engineering tool
connected.
Monitors the number of executions of interrupt programs
using the engineering tool connected.
Forcibly turns on/off the external input/output from the
engineering tool.
Changes a device value for the specified step of a
program, using the engineering tool.
Collects data at a specified interval or a desired timing,
and stores them as a file.
Executes programs written in sequential function chart
(SFC).
Performs PID control by using the PID operation
instruction.
A process control program can be easily created by using
process control function blocks.
Availability according
Reference
to operation mode
Process
Redundant
mode
mode
Page 200 Scan Monitoring
Function
Page 202 Self-Diagnostics
Function
 GX Works3 Operating
Manual
Page 208 Error Clear
Page 211 Event History
Function
 MELSEC iQ-R Online
Module Change Manual
Page 218 Program Cache
Memory Auto Recovery
Function
Page 219 REMOTE
OPERATION
Page 225 BOOT
OPERATION
 GX Works3 Operating
Manual
 GX Works3 Operating
Manual
 GX Works3 Operating
Manual
 GX Works3 Operating
Manual
 GX Works3 Operating
Manual
• Page 232 External
Input/Output Forced On/Off
Function
•  GX Works3 Operating
Manual
• Page 241 Device Test
with Execution Conditions
•  GX Works3 Operating
Manual
• Page 255 DATA
LOGGING FUNCTION
• CPU Module Logging
Configuration Tool Version 1
Operating Manual (MELSEC
iQ-R Series)
 MELSEC iQ-R
Programming Manual
(Program Design)
 MELSEC iQ-R
Programming Manual (CPU
Module Instructions, Standard
Functions/Function Blocks)
 MELSEC iQ-R
Programming Manual (Process
Control Function Blocks/
Instructions)
12 FUNCTION LIST
12
181