When the engineering tool is not connected to the actual system
Set parameters by configuring a system manually on the Module Configuration window of the engineering tool.
4 START-UP PROCEDURE
44
4.8 Setting Parameters
1.
Select a base unit on the Element Selection window, and drag
and drop it to the Module Configuration window.
2.
Drag and drop modules to be used on the base unit placed.
3.
Select [Edit]  [Parameter]  [Fix] on the menu bar.
4.
Click the [Yes] button when the window for adding module labels
of the configured modules appears.
5.
Open the parameter editor of each module by double-clicking the
module.
6.
Set parameters, and click the [Apply] button to close the window.