File Operation Available - Mitsubishi Electric MELSEC iQ-R Series User Manual

Process cpu module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

File operation available

The following lists the file operations which can be executed to each file in the CPU module by external devices.
: Available, : N/A
File type
Program
FB file
Parameter
Device comment
Initial device value
Global label setting file
Initial label value file
Initial global label value file
Initial local label value file
File register
Event history
Device data storage file
General-purpose data
Data logging setting file
Common setting file
Individual setting file
Remote password
Firmware update file
Firmware update prohibited file
Module-specific backup parameter
System file for backing up CPU module data
Backup data file for backing up CPU module data
Device/label data file for backing up CPU module data
System file for the iQ Sensor Solution data backup/
restoration function
Backup data file for the iQ Sensor Solution data backup/
restoration function
System file for automatic restoration with the SD CARD
OFF button
*1 Modification of data in files, such as read/write from/to file register and execution of the FWRITE/FREAD instruction
*2 When the CPU module is in the STOP state, the file operation is performed by writing the FB file to the programmable controller. In the
RUN state, it is performed by online change. Note that only programs and FB files that are registered in the parameter can be written
when the operating status of the CPU module is RUN.
*3 Available only when the CPU module operation status is STOP/PAUSE. A communication error occurs when operated in the RUN state.
*4 Available only when the CPU module operation status is STOP/PAUSE. When a program tries to perform memory operation while the
CPU module is RUN, the operation is continued after the operation status is changed through remote STOP.
*5 Operation on CPU Module Logging Configuration Tool.
*6 When the operation target is the SD memory card, the operation can be performed even while the CPU module is RUN.
*7 The availability of the online change (the file batch online change of FB files and the global label setting file) differs depending on the
model and firmware version.
For supported models and firmware versions, refer to the following.
Page 747 Added and Enhanced Functions
For executable conditions of the file batch online change, refer to the following.
 GX Works3 Operating Manual
When the modules that do not support the online change mentioned above are used, the operation that is performed in the RUN state
continues after the operating status is changed by the remote STOP function.
*8 If the global label that can be accessed from the external device is set and the CPU module is in the RUN state, only read operation is
available.
*9 When the CPU module is in the RUN state, the file operation is available only when the target file is already written to the CPU module.
Operation from engineering
tool
Write
Read
Delete
*2*7
*4
*2*7
*4
*4
*4
*4
*4
*7*8*9
*9
*4
*4
*4
*4
*4
*5
*5
*5
*5
*5
*5
*4
*4
*4
*4
*3
*4
*4
*4
10 MEMORY CONFIGURATION OF THE CPU MODULE
Operation with SLMP and
FTP server function
Write
Read
Delete
*3*6
*3*6
*3*6
*3*6
*3*6
*3
*3*6
*3*6
*3*6
*3*6
*3*6
*3*6
*3
*3*6
*3
*3*6
*3
*3*6
*3*6
*3*6
*3*6
*3
Operation via
10
*1
instruction
Write
Read
153
10.4 Files