Error
Error name
code
1B78H
Tracking
communication
error
1B80H
Tracking
transfer error
1B81H
Tracking
transfer error
1B82H
1BA0H
Redundant
function module
error
36 ERROR CODES
560
36.4 List of Error Codes
Error details and cause
• During tracking transfer, a tracking
communication error occurred. (The
error is detected in the control system
or the standby system. Note that if the
error is detected in the standby
system, the detailed information is not
stored.)
• The tracking data set in the CPU
parameters exceeds the allowable
tracking transfer range. (The error is
detected in the control system.)
• The file register capacity has been set
in the CPU parameters of the control
system CPU module is less than the
file register capacity set for tracking
transfer. (The error is detected in the
control system.)
• The file register data is transferred
from the control system CPU module
to the standby system CPU module
exceeding the capacity of the receive
side. (The error is detected in the
standby system.)
• An error has been detected in the
redundant function module.
Stop/
Action
continue
Continue
• If the other system is powered off,
power on the system.
• If a WDT error has occurred in the
other system CPU module,
eliminate the error cause, and
restart the system.
• Connect tracking cables securely
and properly to the connectors of
the redundant function modules in
both systems.
• Set the program execution time of
the standby system shorter than
that of the control system. If the
shorter value cannot be set,
correct the SD1662 value.
• If the load on the communications
with the external devices via the
other system is high, perform the
communications without going
through the other system or
lighten the load on the
communications.
• Check the power supply status.
• Take measures to reduce noise. If
the same error code is displayed
again, the possible cause is a
hardware failure of the CPU
module, redundant function
module, base unit, or tracking
cable. Please consult your local
Mitsubishi representative.
Continue
• Set the device/label data within
the allowable range in the CPU
parameters ("Tracking Device/
Label Setting").
Continue
• Check and correct the tracking
transfer settings in the CPU
parameters so that they will be
within the device range or the file
register capacity.
• Check and correct the device
settings or the file register capacity
setting in the CPU parameters.
Continue
• Check the detailed information
(system configuration information)
of the error by executing module
diagnostics using the engineering
tool, and check the status of the
redundant function module.
• Take measures to reduce noise. If
the same error code is displayed
again, the possible cause is a
hardware failure of the CPU
module, redundant function
module, or base unit. Please
consult your local Mitsubishi
representative.
Detailed
Diagnostic
information
timing
Data type
At END
(tracking
instruction
transfer)
execution
information
Tracking
At END
transfer
instruction
trigger
execution
information
At END
instruction
execution
System
Always
configuration
information