Trigger setting
Use the event execution type detail setting.
[CPU Parameter]  [Program Setting]
Operating procedure
"Program Setting" window
"Detailed Setting" window
"Event Execution Type Detailed Setting" window
Displayed items
Item
Interruption occurrence
ON of Bit Data (TRUE)
Clear Output and Current Value of
Timer
Passing Time
Unit
Clear Output and
Current Value of
Timer
8 RUNNING A PROGRAM
110
8.5 Program Execution Type
Description
Sets the interrupt pointer used as the trigger.
Sets the device used as the trigger.
Sets that the current values of the output (Y), timer (T),
and long timer (LT) used in this program are cleared at
the execution turn of the event execution type program
that comes after the specified bit data is OFF.
Sets the time passed.
Sets that the current values of the output (Y), timer (T),
and long timer (LT) used in this program are cleared at
the execution turn of the event execution type program
that comes after the specified time passes.
1.
Click "Detailed Setting" on the
"Program Setting" window.
2.
Select the program name and set the
execution type to "Event".
3.
Click "Detailed Setting Information".
4.
Sets the trigger type to execute the
event execution type program.
Setting range
I0 to I15, I28 to I31, I44, I45, I48, I49, I50
to I1023
Page 108 Bit data ON (TRUE)
• Do Not Clear
• Clear
• When "ms" is selected: 1 to 65535ms (in
units of 1ms)
• When "s" is selected: 1 to 65535s (in
units of 1s)
• Do Not Clear
• Clear
Default
Do Not Clear
ms
Do Not Clear