Mitsubishi Electric MELSEC iQ-R Series Module Function Block Reference

Hide thumbs Also See for MELSEC iQ-R Series:

Advertisement

MELSEC iQ-R CPU Module Function Block
Reference

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MELSEC iQ-R Series

  • Page 1 MELSEC iQ-R CPU Module Function Block Reference...
  • Page 3: Table Of Contents

    CONTENTS CHAPTER 1 FUNCTION BLOCK (FB) LIST CHAPTER 2 CPU MODULE FB M+RCPU_MSynchronization_Delay1OUT, M+RCPU_MSynchronization_Delay2OUT ....4 M+RCPU_MSynchronization_Delay1SET, M+RCPU_MSynchronization_Delay2SET ....6 M+RCPU_MSynchronization_Delay1RST, M+RCPU_MSynchronization_Delay2RST.
  • Page 4: M+Rcpu_Msynchronization_Delay1Out

    FUNCTION BLOCK (FB) LIST This chapter lists the FBs for the MELSEC iQ-R series CPU module. FBs for the Ethernet function For the Ethernet function FBs of CPU modules, refer to the "Ethernet-EQUIPPED MODULE FB" in the following.  MELSEC iQ-R Ethernet/CC-Link IE Function Block Reference FBs for the inter-module synchronization function Use this FB when the inter-module synchronization function is used.
  • Page 5 MEMO 1 FUNCTION BLOCK (FB) LIST...
  • Page 6: Chapter 2 Cpu Module Fb

    CPU MODULE FB M+RCPU_MSynchronization_Delay1OUT, M+RCPU_MSynchronization_Delay2OUT Name M+RCPU_MSynchronization_Delay1OUT, M+RCPU_MSynchronization_Delay2OUT Overview Item Description Functional overview Holds the value specified by output request data (input data) in the FB and executes the OUT instruction when the FB is called next or the second time. Symbol M+RCPU_MSynchronization_Delay1OUT o_bData: B...
  • Page 7 FB details Item Description Available devices CPU module RCPU Engineering tool GX Works3 Language Ladder diagram Number of basic steps 12 steps The number of steps of the FB embedded in a program depends on the CPU module used, the input/output definitions, and the options setting of GX Works3.
  • Page 8: M+Rcpu_Msynchronization_Delay1Set, M+Rcpu_Msynchronization_Delay2Set

    M+RCPU_MSynchronization_Delay1SET, M+RCPU_MSynchronization_Delay2SET Name M+RCPU_MSynchronization_Delay1SET, M+RCPU_MSynchronization_Delay2SET Overview Item Description Functional overview Memorizes that this function has been called by the FB and executes the SET instruction when the FB is called next or the second time. Symbol M+RCPU_MSynchronization_Delay1SET o_bData: B B: i_bEN M+RCPU_MSynchronization_Delay2SET o_bData: B B: i_bEN...
  • Page 9: M+Rcpu_Msynchronization_Delay1Set

    FB details Item Description Available devices CPU module RCPU Engineering tool GX Works3 Language Ladder diagram Number of basic steps 12 steps The number of steps of the FB embedded in a program depends on the CPU module used, the input/output definitions, and the options setting of GX Works3.
  • Page 10: M+Rcpu_Msynchronization_Delay1Rst, M+Rcpu_Msynchronization_Delay2Rst

    M+RCPU_MSynchronization_Delay1RST, M+RCPU_MSynchronization_Delay2RST Name M+RCPU_MSynchronization_Delay1RST, M+RCPU_MSynchronization_Delay2RST Overview Item Description Functional overview Memorizes that this function has been called by the FB and executes the RST instruction when the FB is called next or the second time. Symbol M+RCPU_MSynchronization_Delay1RST o_bData: B B: i_bEN M+RCPU_MSynchronization_Delay2RST o_bData: B B: i_bEN...
  • Page 11: M+Rcpu_Msynchronization_Delay1Rst

    FB details Item Description Available devices CPU module RCPU Engineering tool GX Works3 Language Ladder diagram Number of basic steps 12 steps The number of steps of the FB embedded in a program depends on the CPU module used, the input/output definitions, and the options setting of GX Works3.
  • Page 12 M+RCPU_MSynchronization_Delay1MOV, M+RCPU_MSynchronization_Delay2MOV Name M+RCPU_MSynchronization_Delay1MOV, M+RCPU_MSynchronization_Delay2MOV Overview Item Description Functional overview Holds the value specified by transfer source data (input data) in the FB and executes the MOV instruction when the FB is called next or the second time. Symbol M+RCPU_MSynchronization_Delay1MOV o_wData: W B: i_bEN W: i_wData...
  • Page 13: M+Rcpu_Msynchronization_Delay1Mov

    FB details Item Description Available devices CPU module RCPU Engineering tool GX Works3 Language Ladder diagram Number of basic steps • 18 steps (M+RCPU_MSynchronization_Delay1MOV) • 20 steps (M+RCPU_MSynchronization_Delay2MOV) The number of steps of the FB embedded in a program depends on the CPU module used, the input/output definitions, and the options setting of GX Works3.
  • Page 14: Default Value None

    M+RCPU_MSynchronization_Delay1DMOV, M+RCPU_MSynchronization_Delay2DMOV Name M+RCPU_MSynchronization_Delay1DMOV, M+RCPU_MSynchronization_Delay2DMOV Overview Item Description Functional overview Holds the value specified by transfer source data (input data) in the FB and executes the DMOV instruction when the FB is called next or the second time. Symbol M+RCPU_MSynchronization_Delay1DMOV o_dData: D B: i_bEN D: i_dData...
  • Page 15: M+Rcpu_Msynchronization_Delay1Dmov

    FB details Item Description Available devices CPU module RCPU Engineering tool GX Works3 Language Ladder diagram Number of basic steps • 18 steps (M+RCPU_MSynchronization_Delay1DMOV) • 20 steps (M+RCPU_MSynchronization_Delay2DMOV) The number of steps of the FB embedded in a program depends on the CPU module used, the input/output definitions, and the options setting of GX Works3.
  • Page 16 MEMO 2 CPU MODULE FB 2.5 M+RCPU_MSynchronization_Delay1DMOV, M+RCPU_MSynchronization_Delay2DMOV...
  • Page 17: Instruction Index

    INSTRUCTION INDEX ..12 M+RCPU_MSynchronization_Delay1DMOV ..10 M+RCPU_MSynchronization_Delay1MOV ..4 M+RCPU_MSynchronization_Delay1OUT ..8 M+RCPU_MSynchronization_Delay1RST ..6 M+RCPU_MSynchronization_Delay1SET .
  • Page 18 MEMO...
  • Page 19: Revisions

    Japanese manual number: BCN-P5999-0364-C This manual confers no industrial property rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 20: Trademarks

    TRADEMARKS Ethernet is a registered trademark of Fuji Xerox Co., Ltd. in Japan. The company names, system names and product names mentioned in this manual are either registered trademarks or trademarks of their respective companies.   In some cases, trademark symbols such as ' ' or ' ' are not specified in this manual.
  • Page 22 BCN-P5999-0374-C(1703) HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14 , YADA-MINAMI 5-CHOME , HIGASHI-KU, NAGOYA , JAPAN When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission. Specifications subject to change without notice.

Table of Contents