■Setting items
Item
No.
Model Name
Communication Method
Protocol
Fixed Buffer Send/Receive Setting
PLC
IP Address
Port No.
Sensor/Device
MAC Address
Host Name
IP Address
Port No.
Subnet Mask
Default Gateway
Existence Confirmation
Comment can be set on the "Properties" window displayed by right-clicking the module in "List of devices" or
"Device map area" and selecting "Properties". The following can be performed depending on the selected
device.
• Changing the image
• Creating association with a file or application
Description
Connection number for distinguishing settings for each user
connection.
The name of the external device is displayed.
Set the method for communication with the external device.
Communication methods other than "Socket communications" cannot
be set for the CC-Link IE TSN Plus module.
Select the communication protocol for the external device.
For communications using the fixed buffer, select whether to use the
buffer for sending or for receiving in a connection to the external
device.
(This item cannot be set for the CC-Link IE TSN Plus module.)
Displays the IP address of the own node, which is set in "IP Address"
under "Own Node Settings" of "Basic Settings".
Set the port number to be used for communication with the external
device.
Displays the MAC address of the external device.
Displays the name used to identify the external device.
Set the IP address of the external device.
Set the port number of the external device.
Set "65535" to set all the port numbers as the target of data receive.
Displays the subnet mask of the external device.
Displays the default gateway of the external device.
Select the method of alive check that is performed when the Ethernet-
equipped module has not communicated with the external device for a
certain period of time. When the module cannot communicate with the
external device, the connection will be closed. ( Page 84 Existence
Confirmation)
Setting range
The number is set in the following
range starting with 1.
• P1: 1 to 8
• P2: 1 to 8
• Broadcast Send
• Broadcast Receive
• Fixed Buffer (Procedure Exist)
• Fixed Buffer (No Procedure)
• Random Access Buffer
• Predefined Protocol
• Socket Communication
• MELSOFT Connection
• SLMP
• OPS Connection
• MODBUS/TCP
• TCP
• UDP
• Send
• Receive
• Pairing (Receive)
• Pairing (Send)
■P1
1 to 4999, 5012 to 45236, 45240 to
61439, 61443 to 61447, 61449 to
61459, 61465 to 61499, 61502 to
61999
■P2
1 to 2221, 2223 to 4999, 5012 to
44817, 44819 to 49511
(Default: empty)
0.0.0.1 to 223.255.255.254,
255.255.255.255
(Default: empty)
1 to 65534, 65535
(Default: empty)
• KeepAlive
• UDP
• Do not confirm existence
8 PARAMETER SETTINGS
8.1 Parameter Settings for CC-Link IE TSN
8
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r cc-link ie tsn plus