Event
Overview
code
00C61
Time synchronization loss
00C62
Time synchronization error
00C63
Grandmaster switching (CC-Link IE TSN device)
00C64
Grandmaster switching (general-purpose device)
00C65
Time synchronization receive processing failure
00C70
CANopen initialization failure
00C71
Initialization failure (parameter mismatch between
master and slave stations)
00C72
Maximum response time mismatch for the time
managed polling method
00C73
Connection disconnection
00C80
Detection of slave station that does not support the
CC-Link IE TSN Protocol version 2.0
00C81
CC-Link IE TSN Class setting mismatch
Security
Event
Overview
code
10200
Remote password lock
10201
Remote password unlock successful
10202
Remote password unlock failed
10300
Access from IP restricted with IP filter setting
Operation
Event
Overview
code
24100
Own station: Parameter change/new parameter
reception
24300
Own station: Enabling remote device test function
24301
Own station: Failure in enabling remote device test
function (Programmable controller CPU is not in STOP
state (excluding a stop error))
24302
Own station: Failure in enabling remote device test
function (Own station is not set as a master station.)
24303
Own station: Disabling remote device test function
(SB0016 is turned off.)
24304
Own station: Disabling remote device test function
(Programmable controller CPU is in RUN or PAUSE
state).
24305
Own station: Disabling remote device test function
(Programmable controller CPU indicates a stop error.)
24F00
Another station: CPU operating status change
detection
21 EVENT LIST
450
Cause
The time difference between the time notified from the grandmaster and the time of the
own station exceeded the allowable value.
The time synchronization loss occurred more than a fixed number.
The device acting as the grandmaster station was disconnected, and then the CC-Link
IE TSN device was newly selected as the grandmaster.
The device acting as the grandmaster was disconnected, and then the general-purpose
device was newly selected as the grandmaster.
The receive processing for time synchronization failed.
A communication error occurs in CANopen initialization processing.
During initialization processing at the start of control communication, a parameter
mismatch was detected between the master station and slave stations.
A maximum response time mismatch was detected for the time managed polling
method.
Update the engineering tool and slave stations to the latest version.
The connection was cut.
A slave station that does not support the CC-Link IE TSN Protocol version 2.0 was
detected.
A mismatch was detected between the parameter of the master station and the CC-Link
IE TSN Class of the slave stations.
Cause
The lock processing of the remote password was performed.
The unlock processing of the remote password was succeeded.
The unlock processing of the remote password has failed.
Accessed from IP address restricted with the IP filter setting.
Cause
Parameter was changed. Or new parameter was received at power-on.
Remote device test function was enabled.
The operating status of the programmable controller CPU is not in STOP state
(excluding a stop error), and enabling remote device test function failed.
The own station is not set as a master station and enabling remote device test function
failed.
Remote device test function was disabled because SB0016 (Remote device forced
output request) has been turned off.
Remote device test function was disabled because operating status of the
programmable controller CPU has been changed to RUN or PAUSE state.
Remote device test function was disabled because a stop error has occurred in the
programmable controller CPU.
Operating status of the CPU module on another station was changed.