• In a configuration of mixture of CC-Link IE TSN Class B/A, CC-Link IE TSN Class A devices can be connected from a TSN
hub between CC-Link IE TSN Class B devices.
No.0
Class B
No.0: Master station (CC-Link IE TSN Plus module)
No.1: Local station
No.2 to No.7: Remote station
Class A: CC-Link IE TSN Class A device
Class B: CC-Link IE TSN Class B device
• In a configuration of mixture of CC-Link IE TSN Class B/A, connect CC-Link IE TSN Class A devices directly or via a
general-purpose hub when connecting CC-Link IE TSN Class B devices in a line topology.
No.0
Class B
No.0: Master station (CC-Link IE TSN Plus module)
No.1 to No.4: Remote station
Class A: CC-Link IE TSN Class A device
Class B: CC-Link IE TSN Class B device
No.0
Class B
No.0: Master station (CC-Link IE TSN Plus module)
No.1 to No.4: Remote station
Class A: CC-Link IE TSN Class A device
Class B: CC-Link IE TSN Class B device
2 CC-Link IE TSN SYSTEM CONFIGURATION
46
2.2 Structure of CC-Link IE TSN Class B/A Devices and Ethernet Devices
No.1
Class B
TSN HUB
No.1
Class B
No.1
Class B
No.2
Class B
No.5
Class A
General-
purpose hub
No.2
Class A
General-
purpose hub
No.2
Class B
No.3
TSN HUB
Class A
No.4
Class A
General-
No.6
purpose hub
Class A
No.7
Class A
No.3
Class A
No.4
Class A
No.3
Class A
No.4
Class A