8
PARAMETER SETTINGS
8.1
Parameter Settings for CC-Link IE TSN
This chapter describes the parameter settings required for communications with other stations of CC-Link IE TSN.
Procedure for setting parameters
1.
Add the CC-Link IE TSN Plus module (RJ71GN11-EIP) to the engineering tool.
[Navigation window] [Parameter] [Module Information] Right-click [Add New Module]
2.
The required settings, basic settings, and application settings are included in the parameter settings. Select one of the
settings from the tree on the window shown below.
[Navigation window] [Parameter] [Module Information] Target module [Port1 Module Parameter (CC-Link IE
TSN)]
3.
After setting the parameters, click the [Apply] button.
4.
Write parameters to the CPU module using the engineering tool.
[Online] [Write to PLC]
5.
The parameters are reflected by resetting the CPU module or powering off and on the system.
The settings displayed on the required settings, basic settings, and application settings pages (default: ) are
the values that are displayed when the [Restore the Default Settings] button on each window of the
engineering tool is clicked.
8 PARAMETER SETTINGS
8.1 Parameter Settings for CC-Link IE TSN
8
73