Settings; Diagnostics - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

• The torque proving sequence can start when the input signal RUNNING (B3 of
actual signal 03.02) is "1", in other words, when the converter is in operation. After
a successful sequence, the output signal TORQ PROV OK changes to "1".
• If the function detects a fault during the sequence, it keeps the signal TORQ
PROV OK in value "0", changes the signal TORQ PROVE FLT to "1" and trips the
drive.
• Torque proving reference is fixed to 30% of the motor torque (signal TORQ PROV
REF below).
• The torque proving reference is changed from 30 % to 10 % if the High-end limit
(parameter
signal given by the operator.
• The actual torque is read from the signal MOT TORQ (signal 01.05).
<TORQ PROV SEL>
MOTOR TORQUE (1.05)
Running
<TORQ PROV REF>

Settings

Parameter
76.01
...
76.02
76.02
Other
Parameters
42.01

Diagnostics

Actual signal
03.33 bit 2
Faults
TORQ PROVE FLT
10.12
HIGHEND PTR) is true and the drive receives a new start
S
R
<TORQ PROV FLT TD>
I
Additional information
Activates the monitoring
Fault delay time
should be active.
Additional information
Torque prove fault bit
Torque proving not successful
> 1
_
<TORQ PROV SEL>
O
89
Torq prov OK
&
Torq prov flt
Torq prov ref
Program features