Additional Data: Actual Signals And Parameters; Chapter Overview; Terms And Abbreviations; Fieldbus Addresses - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

Additional data: actual signals and parameters

Chapter overview

This chapter lists the actual signal and parameter lists with some additional data. For
the descriptions, see chapter

Terms and abbreviations

Term
PB
FbEq
Absolute Maximum Frequency
Absolute Maximum Speed
W

Fieldbus addresses

Rxxx adapter modules (such as RPBA-01, RDNA-01, etc.)

See the appropriate fieldbus adapter module User's Manual.

Nxxx adapter modules (such as NPBA-12, NDNA-02, etc.)

NPBA-12 Profibus Adapter:
• See column PB in the tables below.
NIBA-01 InterBus-S Adapter:
• xxyy
number
Example: The index number for drive parameter 13.09 is 1309 + 12288 = 13597
(dec) = 351D (hex)
NMBP-01 ModbusPlus Adapter and NMBA-01 Modbus Adapter:
• 4xxyy, where xxyy = drive parameter number
100 + 12288 converted into hexadecimal, where xxyy = drive parameter
·
Actual signals and
parameters.
Definition
Profibus equivalent for drive parameters communicating through
the NPBA-12 Profibus Adapter.
Fieldbus equivalent: The scaling between the value shown on
the panel and the integer used in serial communication.
Value of 20.08, or
20.07
if the absolute value of the minimum limit
is greater than the maximum limit.
Value of parameter 20.02, or
minimum limit is higher than the maximum limit.
Write access is not allowed when the motor is running.
Additional data: actual signals and parameters
20.01
if the absolute value of the
319

Advertisement

Table of Contents
loading

Table of Contents