Set Rec Addr; Set Tr Addr - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

214
Index
Name/Selection
85.09
CONSTANT9
-8388608 to 8388607
85.10
CONSTANT10
-8388608 to 8388607
85.11
STRING1
MESSAGE1
85.12
STRING2
MESSAGE2
85.13
STRING3
MESSAGE3
85.14
STRING4
MESSAGE4
85.15
STRING5
MESSAGE5
90 D SET REC ADDR
90.01
AUX1 DS REF3
0 ... 8999
90.02
AUX1 DS REF4
0 ... 8999
90.03
AUX1 DS REF5
0 ... 8999
90.04
AUX2 DS REF6
0 ... 8999
90.05
AUX2 DS REF7
0 ... 8999
90.06
AUX2 DS REF8
0 ... 8999
90.07
START DS REC
1
10
92 D SET TR ADDR
92.01
MAIN DS STATUS
WORD
302 (fixed)
92.02
MAIN DS ACT1
0 ... 9999
Actual signals and parameters
Description
Sets a constant for the Adaptive Program.
Integer value
Sets a constant for the Adaptive Program.
Integer value
Stores a message to be used in the Adaptive Program (EVENT block).
Message
Stores a message to be used in the Adaptive Program (EVENT block).
Message
Stores a message to be used in the Adaptive Program (EVENT block).
Message
Stores a message to be used in the Adaptive Program (EVENT block).
Message
Stores a message to be used in the Adaptive Program (EVENT block).
Message
- Addresses into which the received fieldbus data sets are written.
- Numbers of the main and auxiliary data sets.
The parameters are visible only when a fieldbus communication is activated
with parameter 98.02. For more information, see chapter
Selects the address into which the value of fieldbus reference REF3 is written.
Parameter index
Selects the address into which the value of fieldbus reference REF4 is written.
Parameter index
Selects the address into which the value of fieldbus reference REF5 is written.
Parameter index
Selects the address into which the value of fieldbus reference REF6 is written.
Parameter index
Selects the address into which the value of fieldbus reference REF7 is written.
Parameter index
Selects the address into which the value of fieldbus reference REF8 is written.
Parameter index
Defines the starting data set from which the drive reads the Control Word,
Reference REF1 and Reference REF2.
Data set number 1 is the starting address. Can be used for standard drives.
Data set number 10 is the starting address. Can be used for multidrives.
Main and Auxiliary Data Sets which the drive sends to the fieldbus master
station.
The parameters are visible only when a fieldbus communication is activated
with parameter 98.02. For more information, see chapter
Stores the address from which the Main Status Word is read from. Fixed value,
not visible.
Parameter index
Selects the address from which the Actual signal 1 is read to the Main Data
Set.
Parameter index
FbEq
1 = 1
1 = 1
-
-
-
-
-
Fieldbus
control.
1
2
Fieldbus
control.