133
To recall the user macro:
• Change the parameter
99.02
APPLICATION MACRO to USER 1 LOAD.
• Press ENTER to load.
The user macro can also be switched via digital inputs (see parameter
16.05
USER
MACRO IO CHG).
Note: The user macro load also restores the motor settings in group
99 START-UP
DATA
and the results of the motor identification. Check that the settings correspond
to the motor used.
Example: You can switch the drive between two motors without having to adjust the
motor parameters and to repeat the motor identification every time the motor is
changed. You only need to adjust the settings and perform the motor identification
once for both of the motors, and then to save the data as two user macros. When the
motor is changed, only the corresponding user macro needs to be loaded, and the
drive is ready to operate.
Application macros, control location EXT1/EXT2