Settings; Diagnostics; Fast Stop - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

118

Settings

Parameter
10.09
11.12

Diagnostics

Actual signal
03.32 bit 0
Warnings
SLOW DOWN UP
SLOW DOWN DOWN

Fast stop

This function is used to ramp down to zero speed according to a predefined
deceleration time (parameter
zero speed on receiving the
PTR should be active (according to the selection of pointer value) for enabling the
Fast stop command. After the command, the input must be inactive for the next start
sequence to happen.
When receiving a Fast stop command, the drive gives a FAST STOP warning
message on the panel.
If the drives are in a Master/Follower configuration and in EXT2 control, all the drives
will stop on a Fast stop command from any of the drives.
Settings
Parameter
10.10
22.10
Diagnostics
Actual signal
03.32 bit 1
Warnings
FAST STOP
Program features
Additional information
Selection for Slowdown
Speed limit during Slowdown
Additional information
Slowdown enabled bit
Slowdown activated in up direction
Slowdown activated in down direction
22.10
FST STP DCCL TIME). The drive decelerates to
10.10
FAST STOP PTR command. The FAST STOP
Additional information
Selection for fast stop
Deceleration time on Fast stop command
Additional information
Fast stop enabled bit
Fast stop is active