Settings; Diagnostics - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

82

Settings

Parameter
15.01
35.01...35.03
Other
Parameters
At the motor end, the cable shield should be earthed through a 10 nF capacitor. If this is not possible,
the shield is to be left unconnected.

Diagnostics

Actual signal
01.35
Warnings
MOTOR 1 TEMP
T MEAS ALM
Faults
MOTOR 1 TEMP
Program features
Additional information
Analogue output in a motor 1 temperature measurement. Set to M1 TEMP
MEAS.
Settings of motor 1 temperature measurement
13.01
to
13.05
(AI1 processing) and
Additional information
Temperature value
Measured motor temperature has exceeded the set alarm limit.
Motor temperature measurement is out of acceptable range.
Measured motor temperature has exceeded the set fault limit.
15.02
to
15.05
(AO1 processing) are not effective.