284
WARNING
CAUSE
LOAD SP DW LIM
The speed reference is limited in the reverse
direction according to the Load speed control
(FFB9)
function.
3.32 CSW bit 6
MACRO CHANGE
Macro is restoring or user macro is being
saved.
(FF69)
MASTERLIM/FLT
Master drive has gone into a fault or has hit
any of the limits. This message is displayed in
(FFB2)
the Follower drives only
MOT CUR LIM
Drive limits motor current according to current
limit defined with parameter
(2300)
CURRENT.
3.18 AW 5 bit 10
(programmable
Fault Function
30.23)
MOTOR STALL
Motor is operating in stall region due to, for
example, excessive load or insufficient motor
(7121)
power.
3.09 AW 2 bit 9
(programmable
Fault Function
30.10)
MOTOR STARTS
Motor identification run starts. This warning
belongs to ID run procedure.
(FF34)
MOTOR TEMP
Motor temperature is too high (or appears to be
too high) due to excessive load, insufficient
(4310)
motor power, inadequate cooling or incorrect
3.08 AW 1 bit 3
start-up data.
(programmable
Fault Function
30.04...30.09)
MOTOR 1 TEMP
Measured motor temperature has exceeded
alarm limit set with parameter 35.02.
(4312)
3.16 AW 4 bit 1
MOTOR 2 TEMP
Measured motor temperature has exceeded
alarm limit set with parameter 35.05.
(4313)
3.16 AW 4 bit 2
Fault tracing
WHAT TO DO
Check motor current settings and group 77
settings.
Wait until drive has finished task.
See Master drive for more detailed description
of fault of limit.
Reduce load or increase ramp time.
20.03
MAXIMUM
Increase parameter
CURRENT value.
Check Fault Function parameters.
Check motor load and drive ratings.
Check Fault Function parameters.
Wait until drive indicates that motor
identification is completed.
Check motor ratings, load and cooling.
Check start-up data.
Check Fault Function parameters.
Check value of alarm limit.
Check that actual number of sensors
corresponds to value set with parameter.
Let motor cool down. Ensure proper motor
cooling: Check cooling fan, clean cooling
surfaces, etc.
Check value of alarm limit.
Check that actual number of sensors
corresponds to value set with parameter.
Let motor cool down. Ensure proper motor
cooling: Check cooling fan, clean cooling
surfaces, etc.
20.03
MAXIMUM