208
Index
Name/Selection
77.10
CURRENT X4 FWD
0.0 ... 3000.0 A
77.11
REF Y4 FWD
0.0 ... 18000.0 rpm
77.12
CURRENT X1 REV
0.0 ... 3000.0 A
77.13
REF Y1 REV
0.0 ... 18000.0 rpm
77.14
CURRENT X2 REV
0.0 ... 3000.0 A
77.15
REF Y2 REV
0.0 ... 18000.0 rpm
77.16
CURRENT X3 REV
0.0 ... 3000.0 A
77.17
REF Y3 REV
0.0 ... 18000.0 rpm
77.18
CURRENT X4 REV
0.0 ... 3000.0 A
77.19
REF Y4 REV
0.0 ... 18000.0 rpm
Actual signals and parameters
Description
Defines the current in amps expected at the base speed in forward direction for
limiting the speed reference to the value in parameter
This current can be the current at the base speed with maximum load when
running in the forward direction.
Setting range in amps.
Defines the speed in rpm to be used as the speed limit in forward direction, if
the current at the base speed in forward direction is equal to the value in
parameter
77.10
CURR X4 FWD. This value can be the minimum allowed
speed in maximum load condition in the forward direction.
Setting range in rpm.
Defines the current in amps expected at the base speed in reverse direction for
limiting the speed reference to the value in parameter
current can be the empty hook current at the base speed when running in the
reverse direction.
Setting range in amps.
Defines the speed in rpm to be used as the speed limit in forward direction, if
the current at the base speed in reverse direction is equal to the value in
parameter
77.12
CURR X1 REV. This value can be the maximum allowed
speed in empty hook condition in the reverse direction.
Setting range in rpm.
Defines the current in amps expected at the base speed in reverse direction for
limiting the speed reference to the value in parameter
Setting range in amps.
Defines the speed in rpm to be used as the speed limit in reverse direction, if
the current at the base speed in reverse direction is equal to the value in
parameter
77.14
CURR X2 REV.
Setting range in rpm.
Defines the current in amps expected at the base speed in reverse direction for
limiting the speed reference to the value in parameter
Setting range in amps.
Defines the speed in rpm to be used as the speed limit in reverse direction, if
the current at the base speed in reverse direction is equal to the value in
parameter
77.16
CURR X3 REV.
Setting range in rpm.
Defines the current in amps expected at the base speed in reverse direction for
limiting the speed reference to the value in parameter
current can be the current at the base speed with maximum load when running
in the reverse direction.
Setting range in amps.
Defines the speed in rpm to be used as the speed limit in reverse direction, if
the current at the base speed in reverse direction is equal to the value in
parameter
77.18
CURR X4 REV. This value can be the minimum allowed
speed in maximum load condition in the reverse direction.
Setting range in rpm.
77.11
REF Y4 FWD.
77.13
REF Y1 REV. This
77.15
REF Y2 REV.
77.17
REF Y3 REV.
77.19
REF Y4 REV. This
FbEq
0 ... 30000
0 ... 180000
0 ... 30000
0 ... 180000
0 ... 30000
0 ... 180000
0 ... 30000
0 ... 180000
0 ... 30000
0 ... 180000