Mot Temp Meas - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

194
Index
Name/Selection
34.05
TORQ ACT FILT TIM
0 ... 20000 ms

35 MOT TEMP MEAS

35.01
MOT 1 TEMP AI1 SEL Activates the motor 1 temperature measurement function and selects the
NOT IN USE
1xPT100
2XPT100
3XPT100
Actual signals and parameters
Description
Defines a filter time for the actual signal torque (actual signal 01.05). Affects
also on the torque read through an analogue output.
Filter time constant
%
Unfiltered signal
100
63
Filtered signal
T
Motor temperature measurement. For the function description, see sections
Motor temperature measurement through the standard I/O interface
81
and
Motor temperature measurement through an analogue I/O extension
on page 83.
sensor type.
Note: If an optional analogue I/O extension module RAIO is used for the
temperature measurement and
MOT 2 TEMP AI2 SEL are set to 1xPT100, analogue extension module input
signal range must be set to 0 ... 2 V (instead of 0 ... 10 V) with DIP switches.
The function is inactive.
The function is active. The temperature is measured with one Pt 100 sensor.
Analogue output AO1 feeds constant current through the sensor. The sensor
resistance increases as the motor temperature rises, as does the voltage over
the sensor. The temperature measurement function reads the voltage through
analogue input AI1 and converts it to degrees centigrade.
The function is active. Temperature is measured using two Pt 100 sensors.
See selection 1xPT100.
The function is active. Temperature is measured using three Pt 100 sensors.
See selection 1xPT100.
-t/T
O = I · (1 - e
I = filter input (step)
O = filter output
t = time
T = filter time constant
t
35.01
MOT 1 TEMP AI1 SEL and/or
FbEq
0 ... 20000
)
on page
35.04
1
2
3
4

Advertisement

Table of Contents
loading

Table of Contents