Settings; Diagnostics; Application Message Blocking - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

Settings

Parameter
77.01
77.03
77.04...77.19

Diagnostics

Actual signal
03.32 bit 10
03.32 bit 5
03.32 bit 6
Warnings
LOAD SP UP LIM
LOAD SP DW LIM

Application message blocking

You can use parameter
messages if you do not need the messages. When a message is blocked, the
relevant function remains in use, but the message itself is not shown on the control
panel display and in the PC tool history.
You can activate or deactivate the messages by setting or resetting the individual
message masking bits. Bit value "1" activates the message: the combined value of
the bits has to be entered in integer format.
The messages and the corresponding masking bits are as follows:
Bit
0
1
2
3
4
5
6
7
8
9
Additional information
Selection of Load speed control
Setting of time period for holding the speed reference at base speed
Setting of speed limits according to motor current at the base speed
Additional information
Load speed control error bit
Speed is limited in the forward direction by the Load speed control function
Speed is limited in the reverse direction by the Load speed control function
Speed limited in the forward direction by the Load speed control function
Speed limited in the reverse direction by the Load speed control function
97.17
Messages
SLOW DOWN UP (FFF4)
SLOW DOWN DOWN (FFF5)
HIGHEND LIMIT (FFF6)
LOWEND LIMIT (FFF7)
LOAD SP UP LIM (FFB8)
LOAD SP DW LIM (FFB9)
JOYSTICK CHECK (FFFA)
ZERO POS WARN (FFFB)
START HIGH (FFB3)
HOMING ACTIVE (FFB1)
HOMING DONE (FFB0)
FLWR1 LIM/FLT (FFFD)
FLWR2 LIM/FLT (FFFE)
FLWR3 LIM/FLT (FFB5)
FLWR4 LIM/FLT (FFB4)
MASTERLIM/FLT (FFB2)
START INTERLOCK
APL LIM WRN MASK to block the application
Default
0
0
0
1
1
1
1
1
1
1
127
Program features