IPC6125-WDL-FA
Configuration Guide
Figure 7-11 SNMP Parameters page
Step 2 Click Add in the SNMP v1/v2c Parameters area.
The page for setting interaction parameters is displayed, as shown in
Figure 7-12 Setting SNMP v1/v2c parameters
Step 3 Set Community name, Confirm name and Community property.
When Community property is set to Readonly, you can only view IPC configurations on the
NMS.
When Community property is set to Read&Write, you can view and modify IPC
configurations on the NMS.
Step 4 Click OK.
The SNMP Parameters page is displayed.
Step 5 Click Save.
----End
7.7.2 Set SNMP Event Trap Parameters
SNMP event trap parameters must be set for the IPC, so the IPC can actively report related
information to the NMS.
All parameters on the IPC except Receiver IP must be the same as those on the NMS. If they
are different, the IPC may fail to report information to the NMS.
Step 1 Choose Settings > Network Configuration > SNMP Parameters.
The SNMP Parameters page is displayed, as shown in