Configuring The Abandoned Object Detection Function - Huawei IPC6125-WDL-FA Configuration Manual

2-megapixel low-light wdr network box camera
Hide thumbs Also See for IPC6125-WDL-FA:
Table of Contents

Advertisement

IPC6125-WDL-FA
Configuration Guide
Step 6 Click Save.
The loitering detection function is configured.
----End
Verification
When an individual loiters in the sensitive area for a time period longer than the value of
Alarm tolerance time:
l
l
9.3 Configuring the Abandoned Object Detection
Function
The abandoned object detection function checks a sensitive area for objects that have been
abandoned for 5 seconds or longer. The system generates an alarm when an abandoned object
is detected.
Prerequisites
Predefined sensitive areas for behavior analysis can be displayed on live video images only
when Video stream type is set to Hybrid stream. To set Video stream type, choose Settings
> System Configuration > Local Parameters.
Issue 01 (2016-08-20)
If the individual is marked with a red box and the individual's movement track is
displayed as a red line on the live video image, loitering detection is successfully
configured.
If the individual is not marked on the live video image, loitering detection is not properly
configured or not enabled.
Table 9-8 Possible causes
Cause
The surveillance area is too large.
The surveillance area is too small.
In the Global configuration area, verify
that Enable is selected.
The sensitive area is not in Enable state
when Behavior type is set to Loitering
detection on the Behavior Analysis
Parameters page.
Video alarm deployment is not Enable
on the Alarm Deployment Policy page
that is displayed when you choose
Settings > Alarm Configuration >
Alarm Deployment Policy.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Table 9-8
lists the possible causes and their solutions.
Solution
Adjust the focal length and dimensions of
the surveillance area to ensure that the
intended object can be detected.
Select Enable.
Select the sensitive area ID from the
sensitive area list and click Enable to
enable the sensitive area.
Select Enable.