Setting Platform Connection Parameters - Huawei IPC6125-WDL-FA Configuration Manual

2-megapixel low-light wdr network box camera
Hide thumbs Also See for IPC6125-WDL-FA:
Table of Contents

Advertisement

IPC6125-WDL-FA
Configuration Guide
Table 3-1 Parameter description
Parameter
Ways to obtain IP
IP address
Subnet mask
Gateway IP address
Preferred DNS server
Alternate DNS server
Step 3 Click Save.
----End

3.2 Setting platform Connection Parameters

IPCs can register with the video surveillance platform using GB/T 28181, SDK, ONVIF, or
GENETEC to view live video viewing, set parameters, and control the PTZ.
Issue 01 (2016-08-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Setting Basic Parameters
Description
Method of obtaining the IP address.
NOTE
l If a Dynamic Host Configuration Protocol
(DHCP) server is configured for the current
network and the IPC automatically obtains its
IP address from the DHCP server, the system
will automatically set the IP address, subnet
mask, gateway IP address, and Domain
Name Server (DNS).
l After the IPC automatically obtains its IP
address from the DHCP server, you can view
the MAC address of the IPC through the
DHCP server and then find the IP address of
the IPC based on the MAC address.
Camera IP address. This parameter is
available only when you set Ways to obtain
IP to Manual.
IP addresses starting with 127 are invalid.
You must enter an IP address starting with
another value that ranges from 1 to 223. The
default value is 192.168.0.120.
NOTE
Click Detect to check whether the IP address is
available.
Subnet mask of the IPC. The default value
is 255.255.255.0.
Gateway IP address of the IPC. The default
value is 192.168.0.1.
IP address of the active domain server. The
default value is 0.0.0.0.
IP address of the standby domain server.
The default value is 0.0.0.0.
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents