Huawei IPC6125-WDL-FA Configuration Manual page 24

2-megapixel low-light wdr network box camera
Hide thumbs Also See for IPC6125-WDL-FA:
Table of Contents

Advertisement

IPC6125-WDL-FA
Configuration Guide
Parameter
Port number
Device ID
Server code
Login name
Password
Registration validity(s)
Heartbeat cycle(s)
Max number of timeout
Issue 01 (2016-08-20)
Description
Port number of the video surveillance platform server. The
default value is 5080.
Unique IPC ID.
NOTICE
The value of this parameter must be the same as the device ID (the
code of the IVS platform, the parameter name is Code) configured on
the video surveillance platform. If they are different, the IPC will fail
to connect to the video surveillance platform.
GB/T 28181 server code.
User-defined the value consists of 20 digits.
NOTICE
The value of this parameter must be the same as the server code set on
the platform.
Login name and domain name used to register the IPC with the
video surveillance platform.
l The value of this parameter is in the login name@domain
name format.
l The login name is the same as the Device ID by default,
and the login name cannot be modified.
l User-defined the domain name consists of 10 digits.
Password for registering the IPC with the video surveillance
platform.
NOTICE
l The value of this parameter must be the same as the registration
password configured on the video surveillance platform. If they are
different, the IPC will fail to connect to the video surveillance
platform.
l To improve security, the password must consist of 8 to 20
characters and contain at least two types of the following: digits,
letters and special characters.
Validity period of the IPC registration with the video
surveillance platform. The default value is 3600.
Time interval for the IPC to send heartbeat messages.
NOTE
l The IPC and platform must have the same heartbeat interval.
l The default heartbeat interval is 60s.
If the number of consecutive heartbeat timeouts reaches the
value specified by Max number of timeout, the IPC cannot
connect to the video surveillance platform.
NOTE
l The value of Max number of timeout for the IPC and platform
must be the same.
l The default value of Max number of timeout is 3.
Huawei Proprietary and Confidential