Fabric Module LEDs
Fabric Module LEDs
Table D-5
Table D-5
Fabric Module LEDs
LED
Status
Status
Green
Red
Flashing red
ID
Flashing blue
Off
Power Supply LEDs
Table D-6
power supplies), there are 1, 2, or 4 input LEDs. The Output, Fault, and ID LEDs have the same function
for both the AC and DC power supply units.
Table D-6
LED
Input 1
Input 2
Input 3
Input 4
Output
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
D-6
describes the fabric module LEDs.
Description
All diagnostics pass. The module is operational (normal initialization sequence).
The diagnostic test has failed. The module is not operational because a fault has occurred during
the initialization sequence.
or
he inlet air temperature of the system has exceeded the safe operating temperature limits of the
T
card (a major environmental warning). The card has been shut down to prevent permanent damage.
The fabric module has just been inserted and is booting up.
or
An overtemperature condition has occurred and the module has powered down.
or
The power was turned off with a CLI command.
or
The module is resetting and both ejector levers are out.
The operator has activated this LED to identify this module in the chassis.
This module is not being identified.
describes the power supply unit LEDs. Depending on the power supply (both AC and DC
Power Supply LEDs
Color
Condition
Green
The AC or DC input voltage is within the valid range.
Off
The AC or DC input voltage is outside the valid range.
Green
The AC or DC input voltage is within the valid range.
Off
The AC or DC input voltage is outside the valid range.
Green
The DC input voltage is within the valid range.
Off
The DC input voltage is outside the valid range.
Green
The DC input voltage is within the valid range.
Off
The DC input voltage is outside the valid range.
Green
The AC or DC output power is within the valid range.
Appendix D
Chassis and Module LEDs
OL-23069-07