Cisco  7000 Installation Instructions Manual
Cisco  7000 Installation Instructions Manual

Cisco 7000 Installation Instructions Manual

Rack-mount kit for cisco 7000 and cisco 7507
Hide thumbs Also See for Cisco 7000:

Advertisement

Doc. No.
78-1058-03
Cisco 7000 and Cisco 7507
Rack-Mount Kit Installation Instructions
Product Numbers: EFT-RMK, ACS-7KRMK and ACS-7KRMK=
Customer Order Number: DOC-781058=
This document provides instructions for installing Cisco 7000 and Cisco 7507 routers in a 19-inch
equipment rack. The rack-mount kit functionality is identical for both chassis. Throughout this
document, the Cisco 7000 and Cisco 7507 chassis are referred to as the chassis.
The sections in this document include the following:
For complete system installation and startup procedures, refer to the Cisco 7000 Hardware
Installation and Maintenance or Cisco 7507 Hardware Installation and Maintenance publications.
Copyright © 1995
Cisco Systems, Inc.
All rights reserved.
Rack-Mount Kit Overview, page 2
— Equipment Rack Descriptions, page 2
— Rack-Mount Installation Summary, page 3
— Mounting Kit Hardware, page 3
Prerequisites, page 7
— Safety Guidelines, page 8
— Equipment Rack Considerations, page 11
— List of Parts and Tools, page 15
Installation, page 16
— Installing the Brackets, page 16
— Attaching the Chassis Ears, page 20
— Installing the Chassis in the Rack, page 21
— Restarting the System, page 26
Cisco Information Online, page 38
1

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Cisco 7000

  • Page 1 Product Numbers: EFT-RMK, ACS-7KRMK and ACS-7KRMK= Customer Order Number: DOC-781058= This document provides instructions for installing Cisco 7000 and Cisco 7507 routers in a 19-inch equipment rack. The rack-mount kit functionality is identical for both chassis. Throughout this document, the Cisco 7000 and Cisco 7507 chassis are referred to as the chassis.
  • Page 2: Cisco 7000 And Cisco

    Failure to read and follow these guidelines could result in an bodily injury or damage to the system chassis or components. This procedure requires two or more people to perform. 2 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions...
  • Page 3: Rack-Mount Installation Summary

    The spanner bars prevent the two brackets from separating. (See Figure 11 on page 19.) Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Rack-Mount Kit Overview...
  • Page 4 (rear) so that you can have access to the power supplies, processor slots, and all status LEDs. 4 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions M4 x 10-mm long Phillips 10-32 x 5/8-inch long Phillips...
  • Page 5 1 inch into the rack to protect the plastic front bezel.) Multiple-chassis rack kits can be stacked in a rack with little or no clearance between the brackets. You can remove the four chassis feet after mounting the chassis in the rack. Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions...
  • Page 6 Rack-Mount Kit Overview Figure 4 shows a typical flush-mount installation. Figure 4 Typical Flush-Mount Installation—For Telco Racks Bolted to the Floor 6 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions...
  • Page 7: Prerequisites

    (For the Cisco 7000, see Figure 16 on page 27, and for the Cisco 7507, see Figure 17 on page 28.) This warning symbol means danger.
  • Page 8: Safety Guidelines

    Do not touch the power supply when the power cord is connected. For systems with a Warning power switch, line voltages are present within the power supply even when the power switch is off and the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected.
  • Page 9 DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position. (For translations of this safety warning, refer to the section “DC Power Disconnection Warning”...
  • Page 10 Do not work on the system or connect or disconnect cables during periods of lightning Warning activity. (For translations of this safety warning, refer to the section “Lightning Activity Warning” on page 34.) 10 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions...
  • Page 11: Equipment Rack Considerations

    A cable retention clip prevents the power supply power cord from being accidentally pulled out of the power supply socket. For a complete description of the power supply, refer to the Cisco 7000 Hardware Installation and Maintenance or Cisco 7507 Hardware Installation and Maintenance publications.
  • Page 12 Foot diameter 1.125 4 places Foot thread size 5/16" 4 places 12 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Power supply/interface processor end 10" clearance required for 16" clearance required interface processor removal for power supply removal 4"...
  • Page 13 Do not use a ramp inclined at more than 10 degrees. (For translations of this safety Warning warning, refer to the section “Ramp Warning” on page 37.) Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 7000 chassis Telco rack...
  • Page 14 Prerequisites Rack Dimensions and Site Layout For complete site requirements and recommendations, refer to the Cisco 7000 Hardware Installation and Maintenance or Cisco 7507 Hardware Installation and Maintenance publications. To help maintain trouble-free operation, consider the following precautions when planning your rack installation: •...
  • Page 15: List Of Parts And Tools

    10-32 x 5/8'' LG Phillips pan-head screws with integral square cone washers As you perform the installation, refer to Figure 2, on page 4, and to the detailed illustrations Note that follow. Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Prerequisites Received...
  • Page 16: Installation

    Mount the bracket with the flange in front of the rack post, and with the inner (shielded) side facing the center of the rack. The ledge should be at the bottom of the bracket. (See Figure 9.) Figure 9 Positioning a Bracket 16 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Flange Rack post...
  • Page 17 flanged front edge of the bracket in front of the rack post. Figure 10 Installing a Bracket on a Rack Post—Left Bracket Shown Flange Rack post Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Installation...
  • Page 18 When the first spanner bar is secured, go around to the other side of the rack and repeat Step 4 Steps 1 through 3 to fasten the remaining spanner bar to its anchor screw. (See Figure 11c.) 18 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions...
  • Page 19 17.5 inches apart (otherwise the chassis will not fit between the brackets). This completes the bracket installation. To install the ears on the chassis, proceed to the next section. Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Installation...
  • Page 20: Attaching The Chassis Ears

    In Figure 12, the example insert on the left shows how the ears attach to the chassis for center mounting. Figure 12 Installing the Ears on the Chassis Center-mount position 20 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Flush-mount position...
  • Page 21: Installing The Chassis In The Rack

    Label the interface cables; you can use the configuration worksheet provided at the end of this document to record the correct cable connections and avoid crossing cables when you reconnect them. (For the Cisco 7000, see Figure 16 on page 27, and for the Cisco 7507, see Figure 17 on page 28.) The power supply switch is also an interlock tab that prevents the supply from being removed when it is on.
  • Page 22 (For the Cisco 7000, see Figure 16 on page 27, and for the Cisco 7507, see Figure 17 on page 28.)
  • Page 23 If your installation requires that the chassis be electrically isolated from the rack, proceed to the next section. Otherwise, proceed to the section “Replacing Power Supplies and Interface Cables” on page 25. Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Chassis foot removal 7/16" nut...
  • Page 24 Note If you are installing a new system, proceed to the Cisco 7000 Hardware Installation and Maintenance or Cisco 7507 Hardware Installation and Maintenance publications for cabling guidelines and further instructions. First-time startup and troubleshooting procedures are not covered in this installation document.
  • Page 25 Step 9 worksheet (if you recorded the cable positions when you disconnected them) to avoid crossing cables. (For the Cisco 7000, see Figure 16 on page 27, and for the Cisco 7507, see Figure 17 on page 28.) Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions...
  • Page 26: Restarting The System

    This procedure is not for new systems; perform this procedure only if you have already connected the network interfaces and performed the first-time startup procedures in the Cisco 7000 Hardware Installation and Maintenance or Cisco 7507 Hardware Installation and Maintenance publications.
  • Page 27 FSIP/HIP/TRIP Router name Location SP RP Chassis serial number Slot 2 Slot 3 Circle one: Circle one: AIP/CIP/EIP/FIP/ AIP/CIP/EIP/FIP/ FSIP/HIP/TRIP FSIP/HIP/TRIP Prepared by Date Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Installation Slot 4 Circle one: AIP/CIP/EIP/FIP/ FSIP/HIP/TRIP...
  • Page 28 Slot 0 Slot 1 Circle one: Circle one: AIP/CIP/EIP/FEIP/FIP/ AIP/CIP/EIP/FEIP/FIP/ FSIP/HIP/TRIP/MIP FSIP/HIP/TRIP/MIP Router name Location 28 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Chassis serial number Slot 4 Slot 2 Slot 3 Circle one: RSP2 RSP2 AIP/CIP/EIP/FEIP/FIP/ FSIP/HIP/TRIP/MIP...
  • Page 29: Translated Safety Warnings

    Do not touch the power supply when the power cord is connected. For systems with a Warning power switch, line voltages are present within the power supply even when the power switch is off and the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected.
  • Page 30: Power Supply Disconnection Warning

    30 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Non toccare l’alimentatore se il cavo dell’alimentazione è collegato. Per i sistemi con No tocar la fuente de alimentación mientras el cable esté enchufado. En sistemas...
  • Page 31: Electric Shock Warning

    Dit toestel kan meer dan één netsnoer hebben. Om het risico van een elektrische Questa unità potrebbe essere dotata di più di un cavo di alimentazione. Per ridurre il Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Translated Safety Warnings...
  • Page 32: Chassis Lifting Warning

    Queste maniglie non sono state progettate per sostenere il peso del telaio. 32 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Puede ser que este equipo posea más de un cable de alimentación. Para reducir el Er zijn twee mensen nodig om het frame op te tillen.
  • Page 33: Dc Power Disconnection Warning

    DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.
  • Page 34: Lightning Activity Warning

    Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar. Varning! 34 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC Antes de proceder con los siguientes pasos, comprobar que la alimentación del...
  • Page 35: Chassis Warning-Rack-Mounting And Servicing

    — Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs avant de monter ou de réparer l'unité en casier. Om lichamelijk letsel te voorkomen wanneer u dit toestel in een rek monteert of Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Translated Safety Warnings...
  • Page 36 — Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de montar o proceder al mantenimiento del equipo instalado en el bastidor. 36 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Per evitare infortuni fisici durante il montaggio o la manutenzione di questa unità in...
  • Page 37: Ramp Warning

    Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden. Non usare una rampa con pendenza superiore a 10 gradi. No usar una rampa inclinada más de 10 grados. Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Translated Safety Warnings...
  • Page 38: Cisco Information Online

    For a copy of CIO’s Frequently Asked Questions (FAQ), contact additional information, contact This document can be used in conjunction with the Cisco 7000 Hardware Installation and Maintenance or Cisco 7507 Hardware Installation and Maintenance publications. (1058rm70.fm) Catalyst, CD-PAC, CiscoFusion, Cisco IOS, CiscoPro, CiscoView, CiscoVision, CiscoWorks, ControlStream, EtherChannel, HubSwitch, LAN Remote Office, LAN...

This manual is also suitable for:

Cisco 7507Eft-rmkAcs-7krmk

Table of Contents