Replacing the Cable Management Frames on the Cisco Nexus 7004 Chassis

To replace storage media on a supervisor module, follow these steps:
Press the Eject Request button for the reader or port that has the media to be replaced.
Step 1
Wait for the reader or port LED to turn off and to see an offline message for that reader or port.
Step 2
Remove the card from the reader.
Step 3
Step 4
Insert the replacement media as follows:
Wait for the reader LED to turn green and for an online message to appear on the console.
Step 5
If you see an offline message or do not see a message, either the card is not fully pushed into the reader
Note
or it is improperly formatted. If the card is fully inserted, either format the card (see the Cisco NX-OS
Fundamentals Configuration Guide) or replace the card with another card that is properly formatted for
the reader.
Replacing the Cable Management Frames on the Cisco Nexus
7004 Chassis
This section describes how to remove and install the cable management frames on the Cisco Nexus 7004
chassis, and it includes the following topics:

Required Tools

You need a flat-blade or number 2 Phillips-head screwdriver with torque capability to loosen or tighten
the screws that hold the frame members to the chassis.

Removing the Cable Management Frames from the Cisco Nexus 7004 Chassis

To remove the cable management frames from the Cisco Nexus 7004 chassis, follow these steps:
Step 1
Unscrew the three M3 screws that hold one of the two cable management frames to the chassis, and
remove that frame from the chassis.
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
10-60
For the Supervisor 1 modules, align the replacement card to the CompactFlash reader slot as shown
in
Figure 4-10 on page 4-17
of the card must begin on the end of the card that goes into the reader first. If the card does not fit
easily into the slot, flip the card so the bottom edge is on top, and try pushing the card into the slot.
For the Supervisor 2 or Supervisor 2E modules, insert the replacement USB drive in the USB port.
Required Tools, page 10-60
Removing the Cable Management Frames from the Cisco Nexus 7004 Chassis, page 10-60
Installing the Cable Management Frames on the Cisco Nexus 7004 Chassis, page 10-61
and push the card all the way into the slot. The grooves on the thin side