I/O Module Leds - Cisco Nexus 7000 Hardware Installation And Reference Manual

7000 series
Hide thumbs Also See for Nexus 7000:
Table of Contents

Advertisement

I/O Module LEDs

I/O Module LEDs

Table D-3
Table D-3
I/O Module LEDs
LED
ID
Status
Link (for each port)
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
D-4
describes the I/O module LEDs.
Status
Description
Flashing blue
The operator has activated this LED to identify this module in the chassis.
Off
This module is not being identified.
Green
All diagnostics pass. The module is operational (normal initialization
sequence).
Red
The module has detected a slot ID parity error and will not power on or boot up.
or
The module is not fully inserted, and it is not making a reliable connection with
the supervisor.
or
The module has failed diagnostic tests and has powered down.
Flashing red
The switch has just been powered on, and the module is resetting.
or
The module is resetting and both ejector levers are out.
or
The module has been inserted during the initialization process.
or
The module could not power up because of insufficient power.
or
An overtemperature condition has occurred. A major temperature threshold has
been exceeded during environmental monitoring.
Off
The module is not receiving power.
Green
The port is active (the link is connected and active).
Orange
The port is disabled by the operator or is not initializing.
Flashing orange The port is faulty and disabled.
Off
The port is not active or the link is not connected.
Appendix D
Chassis and Module LEDs
OL-23069-07

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nexus 7004Nexus 7009Nexus 7010Nexus 7018

Table of Contents