9.3.6 Access rights

The EK205-M has the following access parties.
Access
Meaning
C
Calibration officer
14
CDL
Calibration Manual
A
Administrator
Cu
Customer
-
No access
Every access party has a lock and a matching key.
The access rights apply for both inputs by keyboard and for access via the optical, electrical (fixed
wired) or integrated modem interface. If the lock is closed, all attempts to set values prompt a
corresponding error message (see section 9.3.5, Error messages when entering values).
Reading values via the interfaces is also only possible within the meaning of data protection if a
lock is open.
9.3.6.1 Calibration lock
The calibration lock serves to secure calibration law parameters. These include all values that
influence volume counting and volume conversion.
The calibration lock is designed as a key that is placed within the EK205-M housing below the
circuit board cover. It can be secured with an adhesive label (see section 6.3.1.1, Opening the
calibration lock).
The calibration lock is opened by actuating the key (the P symbol flashes in the display) and
closed again by actuating it a second time (P symbol extinguishes). Closing is also possible by
deleting the St.ES value (see section 9.4.6, Strg. tab (control)) via the keyboard or interface.
Using the enSuite software, it is also possible to set a time in minutes after which the calibration
lock closes automatically.
In particular for applications outside the German calibration obligation or the MID, the protection
degree of all parameters can be changed on request.
As such, parameters that are below the calibration key by default can also be protected with the
administrator key or calibration logbook.
14
If a calibration logbook is available in the device.
89