Honeywell EK205-M Operating Instructions Manual page 58

Volume conversion device
Table of Contents

Advertisement

58
-
Parameters > Interfaces> Connections > Connection 1
-
Parameters > Interfaces> Connections > Connection 2
The two external power for the basic device voltage time windows are set under:
-
Parameters > Interfaces> Connections > Connection 3
-
Parameters > Interfaces> Connections > Connection 4
If you do not need a time window, you can deactivate it by setting the time window start and end to the
same value.
Press the
"Transfer changes to
Battery Life Years
Daily Time Slot Duration
8.1.4.2 Checking GSM field strength
Before starting a data transfer via the modem, you must ensure that there is adequate reception
field strength.
Danger of death!
Ensure that before you switch the external supply for the basic device, the housing on
the EK205-M is securely closed.
For an EK205-M with external supply for the basic device, reconnect the external supply now.
a) Opening the test time window on the device
i
The test time window only needs to be open if none of the time windows 1 to 4 are
open.
i
The use of a test time window is only possible if an appropriate battery for the modem
is available.
Move the cursor to the "Serv." tab in the EK205-M's display, then to
Interfaces> internal modem > CWTst
Press the ENTER key in order to enter the length of the test time window in minutes  "0"
flashes.
Move the cursor with the arrow keys  or  to the digits and change these with the arrow keys
 or  to 10, for example.
After the desired digits have been changed, press the ENTER key in order to confirm the input.
It is possible to abort the entry by pressing the ESC key.
device" icon at the top of the enSuite window.
4 minutes
10 minutes
15 minutes
30 minutes
60 minutes
and
and
Readout Duration
(minutes)
1
2
9.17
6.58
8.43
6.19
7.9
5.9
6.65
5.17
5.05
4.15
Data transfer
5
-
3.45
3.36
3.11
2.7