Honeywell EK205-M Operating Instructions Manual page 74

Volume conversion device
Table of Contents

Advertisement

74
For any further customized settings and tests, click on "Navigation" on the left-hand side
and then on
"Parameterize
i
All the values listed in enSuite under "Parameters" can be found in the "Serv." and "Admin"
display tabs of the EK205-M using the same path.
c) Setting time windows for future data retrievals
In the basic configuration now set up, you can define time windows during which data can be
retrieved cyclically from the EK205-M via the modem. Time windows 1 and 3 are used here
as an example.
You can deactivate time windows which are not needed by setting the start and end of the
time window to the same value.
i
Call acceptance window 1 is closed by default (setting: daily from 00:00 to 00:00).
If you want to transfer data in battery mode, set call acceptance window 1 to the smallest
possible time range in order to protect the battery.
If the EK205-M is operating in battery mode and call acceptance window 1 or 2 is
permanently switched on, the battery may be empty within a few weeks.
• Then click on the
online" at the bottom of the navigation window.
• At the top of the device window, open the path
"Parameters" > "Interfaces" by clicking on the relevant
plus signs, and then select
• Change call acceptance window 1 only if you also want
to transfer data in battery mode. Otherwise, the start
and the end time should each be at "00:00", so that the
battery is saved.
• In call acceptance window 3, set the start to
"00:00" and the end to "23:59".
"Transfer changes to
device" icon at the top of the enSuite window.
"Call time
windows".
Data transfer