Volume conversion device
Table of Contents

Advertisement

Data transfer
i
Make the battery power time windows only as long and frequent as absolutely necessary. Each
time window reduces the EK205-M's battery life.
The editable time windows are not directly accounted for in calculation of expected battery life
of the "Bat.R" EK205-M batteries. Therefore, the expected battery life is not updated, when the
time windows are changed. Past time windows and data transfers are however used in
remaining battery and service life calculation for the "BatRC".
The two battery-power time windows for the basic device are set in the enSuite device window
under:
-
Parameters > Interfaces> Connections > Connection 1
-
Parameters > Interfaces> Connections > Connection 2
The two external supply for the basic device time windows are set under:
-
Parameters > Interfaces> Connections > Connection 3
-
Parameters > Interfaces> Connections > Connection 4
If you do not need a time window, you can deactivate it by setting the time window start and end to the
same value.
Press the
"Transfer changes to
8.1.6.2 Checking GSM field strength
 See section
8.1.4.2
8.1.6.3 Retrieving data with enSuite
a) Opening the test time window for the following test retrievals with TCP/IP
i
The test time window only needs to be open if none of the time windows 1 to 4 are
open.
i
The use of a test time window is only possible if an appropriate battery supply for the
modem is available.
If the communication link to the EK205-M via the optical interface is not set up, it must be created.
( section
Select "Navigation" on the left-hand side of the enSuite window and then
the bottom of the navigation window.
In the top of the device window open the path "Parameters" > "Interfaces" by clicking on the
relevant plus signs, and then select
Click on the "0" value next to
and enter a duration in minutes (i.e. 10), for the test time window for the test retrieval to remain
open. For a battery-operated EK205-M please do not enter an excessively long duration, as
this will adversely affect the battery life.
Press the
"Transfer changes to
The EK205-M is now available via the modem for the duration set.
In enSuite press the "Disconnect" or
interface communication link between enSuite and the EK205-M.
b) Test call up through the TCP/IP network (incl. GPRS network)
Set up the network communication link between enSuite and the EK205-M.
( section 7.3
Once the communication link is set up, you can carry out checks, for instance view certain
parameters. To do this press "Navigation" on the left-hand side of the enSuite window and then
device" icon at the top of the enSuite window.
Checking GSM field strength
7.1 Setting up the communication link to the EK205-M via optical
"Test call acceptance
device" icon at the top of the enSuite window.
"Disconnect from all
Setting up the communication link to EK205-M via a network (TCP/IP)
and
and
(p. 58)
"internal
modem" (not the plus sign before).
window" in the right-hand side of the window
devices" icon to terminate the optical
interface, p. 50)
"Parameterize
online" at
63
)