Honeywell EK205-M Operating Instructions Manual page 100

Volume conversion device
Table of Contents

Advertisement

100
Fig. 40
2
Fig. 41: EK205-M with top assemblies
removed
Ensure that the new basic device battery is fastened correctly and sits tight inside
the EK205-M.
CAUTION!
Damage to property caused by improper device closure!
If the device is not properly closed cables can get pinched and cause damage.
Therefore:
– During closing, ensure the correct position of the cable ducts.
1
4
3
1.
Loosen the four housing screws (Fig. 40: 1 ).
2.
Open the lid of the EK205-M.
3.
Mark the old basic device battery with a felt
pen or label, for instance.
4.
Remove the basic device battery (Fig. 41: 2 )
from its battery holder (Fig. 41: 3 ).
5.
Select the free connection on the plate for
connecting the new battery (K9 or K10; Fig.
41: 4 ).
6.
Place the new basic device battery inside
(Fig. 41: 2 ) and ensure that the battery is
correctly anchored in the battery holder.
7.
Remove the old basic device battery and
dispose of it correctly.
Close the housing using the intended screws
(Fig. 40: 1 ).
9.
Re-enter the start capacity of the battery as
described in section 10.2.2.
10. Check of the operating period calculated as
described in section 10.2.3. In standard
operation mode (see section 4.2.1), the
operation duration must display at least 62
months. Otherwise, compared the settings
with the standard operation case and
execute step 9 if applicable.