Data transfer
a) Close time window / pre-allocate connections
To ensure that parameterization functions correctly, the time windows 1 to 4 need to be closed,
and parameterization of the connections must be pre-allocated. To do this:
Connect a PC or laptop with enSuite installed to the EK205-M optical interface using the
connection cable.
Start enSuite and set up the communication link to the EK205-M using the optical interface.
( section
Send the following files to the EK205-M ( section
Reset all types of connections and time windows to factory setting (*)
Then wait a minute, for any communications activity in progress on the EK205-M to be safely
stopped.
b) Sending parameter file
Send one the following file to the EK205-M ( section
ECM-2G-UG350:
Caution: Even if a GPRS modem is only to be put into operation for GPRS data
transmission in the GSM network, there is a risk that unconscious costs will be
incurred if no APN is entered in the EK205-M AND if an APN is stored on the SIM. In
this case, the modem uses the APN from the SIM and, as a result, every time a
GPRS session is set up (at each time window start), a minimum data volume (e.g. 10
or 100 kB) will be available depending on the provider and the tariff invoice! You can
avoid this by using one of the parameter files listed here.
For the following customized settings and tests required, press "Navigation" on the left-hand
side and then
i
All the values listed in enSuite under "Parameters" can be found on the "Serv." display
tab of the EK205-M under the same path.
c) Setting time window for potential data retrievals
In the base configuration now displayed you can define cyclic time windows, during which data
can be retrieved from the EK205-M via the modem. There are two available time windows, which
operate on EK205-M basic device battery power only and for versions of the EK205-M with
external power supply for the basic device there are two more, which operate only on mains
voltage.
Make the battery power time windows only as long and frequent as absolutely
necessary. Each time window reduces the EK205-M's battery life.
i
The editable time windows are not directly accounted for in calculation of expected
battery life of the "Bat.R" EK205-M batteries. Therefore, the expected battery life is not
updated when the time windows are changed. Past time windows and data transfers
are however used in remaining battery and service life calculation for the "BatRC".
The two battery-power time windows for the basic device are set in the enSuite device window
under:
11
The "x" stands for the version of software on the device, e.g. "2v2".
The asterisk * stands for a small letter which indicates the version of the file, e.g. "a".
7.1 Setting up the communication link to the EK205-M via optical
EK205_1v07.. - int. GPRS-Modem (uBlox)_a.WPP mode only (*)
"Parameterize
online" at the bottom of the navigation window.
7.6 Send parameter
file, p.
11
7.6 Send parameter
57
interface, p. 50)
51):EK205 -M
file, p. 51):
11