46
6.3.1.11
Setting summer time switching
◼
Move the cursor to the "Serv." tab and via the following path to the value "MdTim"
(summer time mode):
Serv.
Date and time
Press the key combination ENTER + The value set flashes.
◼
◼
Change the value using the arrow buttons or :
Mod.Z
Meaning
off
No switching to CEST*
auto
Automatic switching to CEST*
manual
Every year, the start and end of CEST* is set by the control room.
*CEST = Central European Summer Time
Press the ENTER + button to confirm the set value. It is possible to abort the entry
◼
by pressing the key combination ESC + .
6.3.1.12
Delete measurement archives
It is not mandatory to delete the archives on commissioning.
◼
Move the cursor to the "Serv." tab and via the following path to the value "Clr.A" (delete
measurement archives):
Serv.
Edit and delete
All measurement archives (no logbooks) are deleted.
To avoid deleting the archives by mistake, when the calibration lock is open the
serial number (on the type plate of the device) of the EK205-M must be stated.
Press the key combination ENTER + One digit of the value flashes.
◼
◼
Move the cursor with the arrow buttons or to the digits and enter with the arrow
buttons or the serial number of the device.
After stating the serial number of the device, press the key combination ENTER + in
◼
order to confirm the input. It is possible to abort the entry by pressing the key combination
ESC + .
6.3.1.13
Clearing the certification data log
The logbook can only be cleared if the calibration lock is open.
◼
Move the cursor to the "Serv." tab and use the following path to access the value "ClCDL" (Clear
certification data log):
Serv.
Edit and delete
Press the ENTER key combination + "0" will flash.
◼
◼
Change the value to "1" using the or arrow key.
After you have entered the value, press the ENTER key combination + to confirm the
◼
input. The input process can be cancelled by pressing the ESC key combination + .
Installation, connection and commissioning
MdTim
Clr.A
ClCDL