Honeywell EK205-M Operating Instructions Manual page 107

Volume conversion device
Table of Contents

Advertisement

Faults
Message
Description, process
Vb Warn Lim.
The standard volume consumption value monitored (by default: hourly
consumption) is outside the warning limit set.
What value is monitored, and the warning limits can, among other things, be
changed with the enSuite software.
Qm Warn Lim. The operating load (gas flow) is outside the warning limit set.
The warning limit can be changed with the enSuite software.
T Warn Lim.
The gas temperature measured is outside the warning limit set.
The warning limit can be changed with the enSuite software.
p Warn Lim.
The gas pressure measured is outside the warning limit set.
The warning limit can be changed with the enSuite software.
z Warning
The sum of the gas analysis values with AGA-8 DC92 is larger or smaller
than 100%. As such, no correct calculation of the real gas factor and the
compressibility figure could be carried out.
Update error
Before the software update, an error was detected in the cached software
image.
Softw. error
This message is used for factory diagnosis.
Please contact the Elster customer service (see section 1.4 Customer
service).
Sett. error
The programing of the device has generated an unusable combination of
settings.
Please contact the Elster customer service (see section 1.4 Customer
service).
I2 Warn.sig.
If an input has been configured as a warning input, this message will be
displayed if an active signal appears at the corresponding terminal (e.g.
terminal DE2).
The input configuration can be adjusted using the enSuite software.
Batt. low
The remaining battery power is less than six months.
The batteries need to be changed soon.
c) Remarks:
TA Warn Lim.
The ambient temperature measured is outside the warning limit set.
The warning limit can be changed with the enSuite software.
Repair mode
The device is in revision mode
Clock n. set
The internal clock of the Volume Conversion Device has not been adjusted
at the factory.
CDL full
The certification data logbook is full. Changing the parameters marked with
"CDL" without a calibration lock is only possible if the content of the
certification data logbook has been deleted.
U.Logb. full
The software update logbook is full. An update is only possible if the content
of the software update logbook has been deleted.