Error Messages When Entering Values - Honeywell EK205-M Operating Instructions Manual

Volume conversion device
Table of Contents

Advertisement

88
Symbol
Meaning
Signal strength of the radio network for the external modem (connected to the
terminals). This display is only shown if an external modem is connected and
active.
Charging status of the device battery

9.3.5 Error messages when entering values

If a value has been entered incorrectly via the keyboard, then input error messages will be
displayed.
Figure:
--x-- with x = error code according to the following table
Code Description
1
The archive is empty, no values have been entered.
2
The archive value cannot be read.
The archive may currently be opened by the interface for exporting.
4
Parameter cannot be changed (constant)
5
You are not authorized to change this value.
A corresponding lock must be opened to change this value.
6
Invalid value
The value entered is outside the permissible limits.
7
Wrong key
The key entered (number code) is incorrect, lock is not opened.
11
Input not possible due to special settings or configuration, e.g.:
- Change heat value only possible in the gas analysis list; not in the energy list
12
The input of this source (address) is not permitted.
13
Input not possible due to special settings or configuration, e.g.:
The Clr.X function can only be performed once the time has been set to its start value
(initialized) with the button combination
- The Store function can only be executed once the change information for the
alignment of "Vm" (see section 6.3.1.4) or "Vb" (see section 6.3.1.6) was deleted.
14
Gas analysis parameters do not match.
20
Value not defined for the user-specific display
The value to be displayed can be defined by entering the address of the user. As this
address has not yet been entered, no value will be displayed.
21
The value can only be changed when the calibration lock is open as the PTB logbook is
full.
+
.
Operation

Advertisement

Table of Contents