SV2 Series Safety Shut-off Valves
Address
Type
Dec
Hex
9
9
12
C
13
D
49
31
52
34
125
7D
Fuel / Air
127
7F
297
129
298
12A
349
15D
350
15E
351
15F
352
160
353
161
354
162
Valve
Intelligence
Description
Model
Levels
Filtered S1 sensor signal
Stepper motor maximum number of steps.
This value corresponds to the fully opened valve
Valve target ignition position 2 in motor steps during
ignition ramp time
Fuel/Air Module EEPROM status
Fuel/Air Module status
Ignition Learnt Pos. 2
V2V
Standard
Full valve stroke in motor steps
Target amplification
Fuel/air curve informational flags related to curve
loading and saving
X-coordinate 0
X-coordinate 1
X-coordinate 2
X-coordinate 3
X-coordinate 4
X-coordinate 5
Data
Content
Type
Dimensionless
- Represents mass flow of air in the appliance.
- Can also represent gas flow in the appliance if the Lambda
S16
value is held constant.
- When linking this value to fan speed, consideration must be
given to relative changes in air density.
Position scaled by 4
U16
(i.e. value of 4 is one full step)
Position scaled by 4
U16
(i.e. value of 4 is one full step)
0 =There has not been communication with EEPROM
1 =Communication with EEPROM is OK
3 =EEPROM data matches RAM storage
Ehum
0x81=Communication error
0x82=EEPROM writing failed
0x84=RW data inconsistency
0x88=RO data inconsistency
0
1
Enum
3
0xA1=EEPROM data inconsistency
0xC1=Communication error
Position scaled by 4
S16
(i.e. value of 4 is one full step)
Position scaled by 4 (i.e. value of 4 is one full step) run
S16
between end stops in the last detection cycle.
Current gain value based on current fuel/air curve and
settings.
S16
Value scaled by 1x104
Bit 0: True = if new curve point is added, it will replace
another existing point. 0 = a new point will be added to the
curve.
Bit 1: True/False = the fuel/air curve commissioning mode
is active/inactive.
Bit 2: True = a fuel/air curve maximum point already exists.
Bit 3: True = point commissioning is currently active.
Bit 4: True = a fuel/air curve minimum point already exists.
U16
Bit 5: True = an initial fuel/air curve already exists.
Bit 6: True = a fuel/air curve point is being sampled.
Bit 7: True = the fuel/air curve is locked.
Bit 8: True = the loaded fuel/air curve data is OK and can
be stored. Updated when the fuel/air curve is unlocked for
editing.
Bit 9: True = a new fuel/air curve point has been saved.
X-coordinate of CORRECTION fuel/air curve, S1 sensor
value.
S16
S1 value is dimensionless.
-32768 indicates an empty cell
224
=Disabled
=Enabled
=OK
32-00029—02