Power Supply Connection Ts-X Ts-P - Yamaha TS-S User Manual

Yamaha single-axis robot controller ts series
Table of Contents

Advertisement

3.2
Power supply connection TS-X TS-P
Use the power connector supplied with the controller to connect the power supply.
Power supply connector terminal names and functions
n
Power supply connector (TS-X 205, 210, 220 TS-P 205, 210, 220 200VAC specs.)
Signal Name
L
Main power input
200 to 230VAC ±10%, 50/60Hz
N
Control power input
L1
200 to 230VAC ±10%, 50/60Hz
Consumption current
N1
150mA MAX
Power supply connector (TS-X 105, 110 TS-P 105, 110 100VAC specs.)
Signal Name
L
Main power input
100 to 115VAC ±10%, 50/60Hz
N
NC
No connection
Control power input
L1
100 to 115VAC ±10%, 50/60Hz
Consumption current
N1
300mA MAX
Power supply connection examples
n
For 200VAC power supply:
For 100VAC power supply:
c
CAutIoN
• Be sure that the power supply voltage and the terminal connections are correct. Incorrect voltage and
connections could cause an equipment failure.
• Shut the control power off while in a "servo off" condition.
Description
Description
Wiring breaker
Noise filter
200VAC
Surge
absorber
Wiring breaker
Noise filter
100VAC
Surge
absorber
Controller
AC IN
Electromagnetic
contactor
L
N
L1
N1
Controller
AC IN
Electromagnetic
contactor
L
N
NC
L1
N1
2
23202-M1-00
23203-M1-00
2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts-shTs-s2Ts-xTs-p

Table of Contents