Cisco MDS 9000 series Command Reference Manual page 80

Hide thumbs Also See for MDS 9000 series:
Table of Contents

Advertisement

Searching and Filtering CLI Output
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
vsan 1 wwn 28:12:00:05:30:00:06:ea fcid 0x680004 dynamic
vsan 1 wwn 28:13:00:05:30:00:06:ea fcid 0x680005 dynamic
vsan 1 wwn 28:14:00:05:30:00:06:ea fcid 0x680006 dynamic
vsan 1 wwn 28:1f:00:05:30:00:06:ea fcid 0x680007 dynamic
vsan 1 wwn 28:20:00:05:30:00:06:ea fcid 0x680008 dynamic
vsan 1 wwn 21:00:00:e0:8b:05:76:28 fcid 0x680100 area dynamic
vsan 1 wwn 20:c5:00:05:30:00:06:de fcid 0x680200 area dynamic
vsan 1 wwn 28:2b:00:05:30:00:06:ea fcid 0x680012 dynamic
vsan 1 wwn 28:2d:00:05:30:00:06:ea fcid 0x680013 dynamic
vsan 1 wwn 28:2e:00:05:30:00:06:ea fcid 0x680014 dynamic
vsan 1 wwn 28:2f:00:05:30:00:06:ea fcid 0x680015 dynamic
vsan 1 wwn 28:30:00:05:30:00:06:ea fcid 0x680016 dynamic
--More--
The following is partial sample output of the show tech-support EXEC command. It begins displaying
unfiltered output with the first line that contain the string
switch# show tech-support | begin "show interface brief"
-------------------- show interface brief ------------------
-------------------------------------------------------------------------------
Interface
-------------------------------------------------------------------------------
fc4/1
fc4/2
fc4/3
fc4/4
fc4/5
fc4/6
fc4/7
fc4/8
fc4/9
fc4/10
fc4/11
fc4/12
fc4/13
fc4/14
fc4/15
--More--
The following is partial sample output of the show running-config | exclude EXEC command. It
excludes any output line that contain the pattern
switch# show running-config | exclude vsan
version 2.1(1a)
poweroff module 9
fcdomain fcid database
ssm enable feature nasb interface fc4/1-4
ssm enable feature santap module 4
ssm enable feature nasb interface fc9/1-4
ssm enable feature santap interface fc9/5-8
ssm enable feature santap interface fc9/21-28
switchname switch
boot kickstart bootflash:/b2193 sup-1
boot system bootflash:/r2193 sup-1
boot kickstart bootflash:/b2193 sup-2
boot system bootflash:/r2193 sup-2
boot ssi bootflash:/laslc1.bin module 1
boot ssi bootflash:/laslc1.bin module 2
boot ssi bootflash:/laslc1.bin module 3
boot ssi bootflash:/laslc1.bin module 4
boot ssi bootflash:/laslc1.bin module 7
Cisco MDS 9000 Family Command Reference
1-22
Vsan
Admin
Admin
Status
Mode
Trunk
Mode
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
1
FX
--
up
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
1
E
on
notConnected
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
1
FX
--
sfpAbsent
show interface brief
FCOT
Oper
Oper
Mode
Speed
(Gbps)
--
--
--
--
--
--
--
--
swl
F
--
--
--
--
--
--
swl
--
--
--
--
--
--
--
--
--
--
--
--
--
.
vsan
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 1
CLI Overview
.
Port
Channel
--
--
--
--
1
--
--
--
--
--
--
--
--
--
--
--

Advertisement

Table of Contents
loading

Table of Contents