Thermal rules

This topic provides thermal rules for the server.
"Typical configurations" on page 59
"Storage configurations" on page 60
"GPU configuration" on page 60
Abbreviations used in tables below are defined as follows:
• Max.Temp.: Maximum ambient temperature at sea level
• FIO = riser 5 + front OCP
• S/S: SAS/SATA
• Any: AnyBay
• S: standard
• P: performance
• NA: not applicable
• Y: yes
• Y* in the Support middle bays or Support rear bays column: yes (when no Gen5 7.68 TB or larger
capacity NVMe drive is installed)
• Y* in the Support DIMMs >= 96 GB column: yes (when no ThinkSystem 96GB TruDDR5 4800MHz (2Rx4)
RDIMM-A or ThinkSystem 128GB TruDDR5 4800MHz (4Rx4) 3DS RDIMM-A v1 is installed)
• N: no
Processor groups are defined as follows:
• Group B: 200 W ≤ cTDP ≤ 240 W
• Group A: 240 W < cTDP ≤ 300 W
• Group E: 320 W ≤ cTDP ≤ 400 W
Typical configurations
This section provides thermal information for typical configurations.
Front bays
Max. Temp.
45°C
35°C
• 8 x 2.5"
• 16 x 2.5"
• 8 x 3.5"
30°C
25°C
Notes:
• Group E
1
processors include 9654(P), 9554(P), 9174F, 9754, and 9734.
• When a part with active optical cable (AOC) is installed and the rate of the part is greater than 25 GB, the
ambient temperature must be limited to 30°C or lower.
• When the following parts are installed, the ambient temperature must be limited to 35°C or lower.
– Broadcom 57416 10GBASE-T 2-port OCP
– Broadcom 57454 10GBASE-T 4-port OCP
– Network interface cards (NICs) at a rate greater than or equal to 100 GB
– Parts with AOC and at the rate of 25 GB
Processor
Heat sink
Group B
2U P
Group B
2U S
Group B, A
2U S
Group B, A
2U S
Group E
1
2U P
Group E
2U P
Fan type
Air baffle
S
P
S
S
S
P
S
P
S
P
S
P
.
Chapter 5
Hardware replacement procedures
Support
DIMMs >= 96
GB
N
N
Y
Y
Y*
Y
59