– Never hold two or more memory modules together so that they do not touch each other. Do not stack
memory modules directly on top of each other during storage.
– Never touch the gold memory module connector contacts or allow these contacts to touch the outside
of the memory module connector housing.
– Handle memory modules with care: never bend, twist, or drop a memory module.
– Do not use any metal tools (such as jigs or clamps) to handle the memory modules, because the rigid
metals may damage the memory modules.
– Do not insert memory modules while holding packages or passive components, which can cause
package cracks or detachment of passive components by the high insertion force.
• In the case of processor board replacement, keep records of the slots in which the modules are installed,
and make sure to install them back to the exact same slots after processor board replacement.
• If you are not installing a replacement memory module to the same slot when processors with TDP greater
than 240 W are installed, make sure you have memory module filler available.
Procedure
Attention: Make sure to remove or install memory module 20 seconds after disconnecting power cords from
the system. It allows the system to be completely discharged of electricity and safe for handling memory
module.
Step 1.
Make preparation for the task.
a.
Power off the server and peripheral devices and disconnect the power cords and all external
cables. See
b.
If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
c.
Remove the top cover. See
d.
If your server comes with an air baffle or a middle cage, remove it. See
on page 70
e.
Locate the memory module slots and determine which memory module you want to remove
from the server.
Step 2.
Remove the memory module from the slot.
Attention: To avoid breaking the retaining clips or damaging the memory module slots, handle the
clips gently.
"Power off the server" on page
"Remove the top cover" on page
or
"Remove the middle drive cage and drive backplanes" on page
62.
"Remove the server from rack" on page
277.
.
Chapter 5
Hardware replacement procedures
63.
"Remove the air baffle"
162.